timer mode

This unit can be programmed to start and run the engine every three hours. The engine will run for the pro-

grammed run time and then shut down. After three hours, the unit will restart the engine. A maximum of six

cycles can occur.

IMPORTANT! Timer Mode should be used only in open areas. Never start and run the vehicle in an
enclosed space such as a garage or carport.

The same procedure may be used to enter or exit Timer Mode using the remote transmitter:

1. Remote start the vehicle.

2. Press and release the transmitter button(s) controlling Channel Two.

3. Press and release the transmitter button(s) controlling remote start operation.

When entering Timer Mode, the engine should shut down. The parking lights (if connected) will flash four times

and the engine will restart. The system is in Timer Mode. The engine may be allowed to run for its programmed

run time, or the transmitter can be used to shut down the engine. Either way, the remote start system will restart

the engine again in three hours. Timer Mode is exited automatically after the sixth run cycle.

Timer Mode can also be exited manually as follows:

1. Make sure the remote start system is not operating the engine.

2. Turn the ignition on.

Timer Mode will be exited and the parking lights will flash four times.