Shutdown diagnostics – Avital AviStart 3000 User Manual
Page 35
© 2001 Directed Electronics, Inc. Vista, CA
35
shutdown diagnostics
The unit has the ability to report the cause of the last shutdown of the remote start system. To enter diagnostic mode:
1.
Turn the ignition off.
2.
Press and HOLD the Program switch.
3.
Turn the ignition on and then off.
4.
Release the Program switch.
5.
Press and release the Program switch.
The LED will now report the last system shutdown by flashing for one minute in the following grouped patterns:
The LED will stop flashing when the ignition is turned on.
LED SHUTDOWN
FLASHES
MODE
One
System timed out
Two
Over-rev shutdown
Three
Low or no RPM
Four
Transmitter Shutdown (or optional push-button)
Five
(-) Shutdown
Six
(+) Shutdown
Seven
(-) Neutral safety shutdown (H2/6 BLACK/WHITE)
Eight
Wait-to-start timed out