shutdown diagnostics

The unit has the ability to report the cause of the last shutdown of the remote start system. To enter diagnostic mode:

1.

Turn the ignition off.

2.

Press and HOLD the Program switch.

3.

Turn the ignition on and then off.

4.

Release the Program switch.

5.

Press and release the Program switch.

The LED will now report the last system shutdown by flashing for one minute in the following grouped patterns:

The LED will stop flashing when the ignition is turned on.

LED SHUTDOWN
FLASHES

MODE

One

System timed out

Two

Over-rev shutdown

Three

Low or no RPM

Four

Transmitter Shutdown (or optional push-button)

Five

(-) Shutdown

Six

(+) Shutdown

Seven

(-) Neutral safety shutdown (H2/6 BLACK/WHITE)

Eight