beautypg.com

Avital AviStart 3000 User Manual

Page 24

background image

24

© 2001 Directed Electronics, Inc. Vista, CA

Interfacing with a reversing polarity system requires either two relays or one 451M (not included).

It is critical to identify the proper wires and locate the master switch to interface properly. Locate wires that

show voltage on lock and unlock. Cut one of the suspect wires and check operation of the locks from both

switches. If one switch loses operation in both directions and the other switch operates in one direction only,

you have located one of the target wires. The switch that lost all operation is the master switch. If one switch

works both directions and the other switch works only one direction, you have a Type A system. If both switches

still operate, but one or more doors have stopped responding entirely, you have cut a motor lead. Reconnect it

and continue to test for another wire. Once both wires have been located and the master switch identified, cut

both wires and interface as shown below.

IMPORTANT! If these are not connected properly, you will send (+)12 volts directly to (-) ground,
possibly damaging the alarm or the factory switch.

type C: reversing polarity