Page 2: Automated external defibrillator trainer2, Aha/erc 2010

Additional Remote Controllers are available.
Contact ZOLL Medical Corporation or your distributor.
1.
Keep Trainer2 and Remote Controller clean, undamaged,
and free of excessive wear.
2.
Verify that there are no cracks or loose parts in Trainer2 and
Remote
Controller.
3.
Replace Training electrodes as necessary.
MAINTENANCE
Trainer2 does not respond
(green light in status window
is not lit) when On/Off
Button is pushed
TROUBLESHOOTING
Clean the Trainer2 unit and remote controller with soft, damp
cloth using soap and water, then wipe dry immediately.
Do not immerse any parts in water.
Do not clean with ketones (e.g., MEK, acetone).
Avoid using abrasives on any surface.
Do not sterilize the Trainer2 or the Remote Controller.
CLEANING
TRAINING USE ONLY - NOT FOR CLINICAL USE
REF 9650-0090-01 Rev. C
Product intended for indoor use only.
Do not attempt to plug AED Plus or AED Pro
simulator into connector of Trainer2.
This device is for training only. It will not deliver defibrillation energy.
Replace all four D batteries
in Trainer2 unit.
Remote Controller does not
respond (scenario
selection is not lit)
when View/Enter
Button is pushed.
Replace both AA batteries in
Remote Controller.
With new batteries in both,
Trainer2 fails to respond to
Remote Controller.
AED Plus Trainer2 problem/
display:
Action:
Contact ZOLL
Technical Service.
Do not attempt to take Trainer2 or Remote Controller apart.
Trainer2 does not beep or
react to Remote Controller
during CPR interval.
Re-set scenario and make
certain that CPR metronome
light is on.
Trainer2 announces breathing
prompts, OPEN AIRWAY and
CHECK BREATHING.
Unit is configured for ERC.
Change to AHA configuration.
(See Switching AHA/ERC
Configuration section of this
Operator’s Guide).
SWITCHING AHA/ERC CONFIGURATION
American Heart Association (AHA) configuration: No prompts for
breathing.
European Resuscitation Council (ERC) configuration: Contains breathing
prompts OPEN AIRWAY and CHECK BREATHING.
To switch between either AHA or ERC configuration, do the following:
With the Trainer2 unit off, hold down the Shock Button. Press On/Off Button
once. Green light will illuminate at status window to indicate AHA
cofiguration (prompt sequence will contain no breathing prompts).
Press Shock Button again. Green light will turn off and red light will illuminate
at status window to indicate ERC configuration (prompt sequence will
contain breathing ).
Press Shock Button again to revert to AHA configuration (green light on
and red light off).
When configured as desired (green = AHA, red = ERC), hold down On/Off
Button to turn unit off to store configuration.
WARNINGS
Remove battery compartment doors only to replace batteries.
Medical Electrical Equipment needs special precautions regarding
EMC and needs to be installed and put into service according to the
EMC information provided in accompanying documents.
Portable and Mobile RF Communications equipment can affect
Medical Electrical Equipment.
SYMBOLS
The following symbols appear on the ZOLL AED Trainer2:
Temperature limitation.
Manufacturer.
Authorized representative in the European Community.
Caution.
Return to a collection site intended for waste electrical and electronic
equipment (WEEE). Do not dispose of in unsorted trash.
REF
Catalogue Number.
NOTE
Conformité Européene - Complies with Low Voltage Directive 73/23/EEC.
ZOLL Medical Europe
Newtonweg 18
6662 PV ELST
The Netherlands
Tel: +31 (0) 481 366410
Fax: +31 (0) 481 366411
International Service: Contact your
local distributor.
VF 1
VF 2
VF 3
VF 4
Done
Shock
CPR
Shock
CPR
1
Simulated heart rhythm: Student Response:
ASYSTOLE 1
ASYSTOLE 2
VF 1
VF 2
Done
No Shock
CPR
Shock
CPR
2
Simulated heart rhythm: Student Response:
VF 1
VF 2
NSR 1
NSR 2
Done
Shock
CPR
No Shock
CPR
3
Simulated heart rhythm: Student Response:
ASYSTOLE 1
ASYSTOLE 2
ASYSTOLE 3
ASYSTOLE 4
Done
No Shock
CPR
No Shock
CPR
4
Simulated heart rhythm: Student Response:
SCENARIOS
ACCESSORIES
You can order the following Trainer2 accessories from the ZOLL
Customer Service Department or your distributor:
Item:
REF
1. CPR-D padz
®
Training Electrodes (1 Set)
8900-0804-01
2. CPR-D padz Training Gel (5 Pair)
8900-0803-01
3. stat-padz
®
Training Electrodes (1 Set)
8900-0805-01
4. pedi-padz
®
II Training Electrodes (case of 6)
8900-000861-01
5. Trainer2 Remote Controller
8008-0007
6. Trainer Carrying Case
8000-0375-01
7. Trainer Demo Manikin
8000-0835-01
ZOLL, AED Plus, Real CPR Help, CPR-D padz, stat-padz and pedi-padz are trademarks or
registered trademarks of ZOLL Medical Corporation in the United States and/or other countries.
Copyright 2012 by ZOLL Medical Corporation
.
All rights reserved.
© 2012 ZOLL Medical Corporation
On
Off
For technical support or repair:
ZOLL Medical Corporation
269 Mill Road
Chelmsford, MA USA 01824-4105
Attn:
Technical Service Department
Tel: 978-421-9655 800-348-9011
Fax: 978-421-0001
AED Plus
Trainer2
Automated External Defibrillator Trainer2
Operator’s Guide
AHA/ERC 2010
®