beautypg.com

26 hood service procedures – XLT XD-9006B User Manual

Page 26

background image

Technical Support US: 888-443-2751

Technical Support INTL: 316-943-2751

26

HOOD SERVICE PROCEDURES

Complete VFD manual available at

www.xltovens.com

.

Hitachi X200 Restoring AVI Defaults

Access program parameters by pressing the button one time and using the up and down
arrow buttons to navigate to the appropriate parameter. Press the button again to make
adjustments to that parameter by using the up and down arrows. To store the new settings press the
button one time.

B031 = 01
B084 = 01

Press and hold the and buttons all at the same

time. Release the buttons all at once and the country code should appear in the dis-
play (USA). Hitachi’s factory settings are now restored.

To install AVI Defaults press button one time and enter following parameters

A001 = 01
A003 – USA = 60 Hz.

World = 50 Hz.

A082 = Supply voltage at

location 200, 215, or

230 choose appropriate

voltage.

A093 = 3000
A094 = 01
A096 = 10
B002 = 25
C001 = 02
C002 = 03
C003 = 04
C004 = 05
C014 = 00
F001 = See Figure 1
H004 = 4
B031 = 03

Put controller into display mode by pressing the button and holding until d001 appears

on the display release and then press the button one time. The display should show
0.0.

Test run the motor by turning on one of the oven/hood switches located on the face of the hood.

Read the entire instruction before programming.

TIP