26 hood service procedures – XLT XD-9006B User Manual
Page 26
![background image](/manuals/355634/26/background.png)
Technical Support US: 888-443-2751
Technical Support INTL: 316-943-2751
26
HOOD SERVICE PROCEDURES
Complete VFD manual available at
Hitachi X200 Restoring AVI Defaults
Access program parameters by pressing the
arrow buttons to navigate to the appropriate parameter. Press the
adjustments to that parameter by using the up and down arrows. To store the new settings press the
B031 = 01
B084 = 01
Press and hold the
time. Release the buttons all at once and the country code should appear in the dis-
play (USA). Hitachi’s factory settings are now restored.
To install AVI Defaults press
A001 = 01
A003 – USA = 60 Hz.
World = 50 Hz.
A082 = Supply voltage at
location 200, 215, or
230 choose appropriate
voltage.
A093 = 3000
A094 = 01
A096 = 10
B002 = 25
C001 = 02
C002 = 03
C003 = 04
C004 = 05
C014 = 00
F001 = See Figure 1
H004 = 4
B031 = 03
Put controller into display mode by pressing the
on the display release and then press the
0.0.
Test run the motor by turning on one of the oven/hood switches located on the face of the hood.
Read the entire instruction before programming.
TIP