Oven service procedures – XLT XD-9006B User Manual
Page 24
Technical Support US: 888-443-2751
Technical Support INTL: 316-943-2751
24
Figure 5
Check Low Bias Pressure:
Pull one of the two blue wires going into the modulating valve. (This simulates a temperature
drop and allows the oven to run at Low Flame Bias)
If the flame goes out turn the 5mm screw clockwise 1 turn to increase Low Flame
Bias
Wait 30 seconds and the oven will re-light.
Using a 5mm socket turn the Low Flame Bias screw (Figure 6) until desired setting is
achieved. Use (Figure 5) for correct valve settings.
Figure 6
OVEN SERVICE PROCEDURES
Multi-Valve Adjustment Procedure
NOTE
5 mm
W/C
mbar
kPa
W/C
mbar
kPa
3.5
8.75
0.875
10
25
2.5
0.1
0.25
0.025
0.1
0.25
0.025
Multi-Valve Adjustment Settings
All Oven Models
Natural Gas
LP Gas
Low Flame Bias
High Flame Bias