Avi recommended exhaust flow rates – XLT XD-9004A User Manual
Page 59

59
Technical Support US: 888-443-2751
Technical Support INTL: 316-943-2751
NOTE: Most building codes require 500 Feet per Minute velocity. Exhaust duct is 1 ft
2
. Check
with your local building official for requirements.
Top Middle Bottom
187.5
187.5
93.75
93.75
[57.15]
[57.15]
[28.58]
[28.58]
187.5
187.5
93.75
93.75
[57.15]
[57.15]
[28.58]
[28.58]
189.75
241.5
155.25
181.125
[57.84]
[73.61]
[47.32]
[55.21]
189.75
241.5
155.25
181.125
[57.84]
[73.61]
[47.32]
[55.21]
187.5
187.5
93.75
93.75
[57.15]
[57.15]
[28.58]
[28.58]
189.75
241.5
155.25
181.125
[57.84]
[73.61]
[47.32]
[55.21]
287.25
365.625
235.125
274.3125
[87.55]
[111.44]
[71.67]
[83.61]
189.75
241.5
155.25
181.125
[57.84]
[73.61]
[47.32]
[55.21]
287.25
365.625
235.125
274.3125
[87.55]
[111.44]
[71.67]
[83.61]
287.25
365.625
235.125
274.3125
[87.55]
[111.44]
[71.67]
[83.61]
287.25
365.625
235.125
274.3125
[87.55]
[111.44]
[71.67]
[83.61]
Single
X
Double
X
Switches On
18xx
24xx
32xx
38xx
Exhaust Flow Rates VELOCITY (min. recommended)
X
Triple
X
X
X
X
X
X
X
X
X
NOTE: Figures represent VELOCITY measured at the Grease Filter.
X
X
X
NOTE: All values are FPM [M/Min] unless otherwise noted.
X
X
AVI RECOMMENDED EXHAUST FLOW RATES
The VELOCITY readings above are obtained by holding an anemometer 3” away from the Grease
Filter. Take several readings in different locations across the filters and average the results.