#34 Main power switch
#35 Fuse (see page 14)
#36 Power connection
#38 Serial port for external remote controlling
#39 Parallel port for external remote controlling
#41 Power output for lightbox (12 V DC) (see page 9)
#42 RGBS-output 1(switchable - details see below)
#43 Preview RGBS-output (not switchable - details see below)
#44 RGBS-output 2 (switchable - details see below)

CONNECTIONS

(VZ-45b)

The VZ-45b outputs an RGBS-signal with 50 Hz and 31.25 kHz.
This is a DATA-RGBS signal which can be used by most data-projectors or computer-monitors
.
However, you can NOT connect the VZ-45b to a video monitor or a video-projector which can not project
computer data (with a resolution of at least 782 x 582 pixels or 31.25 kHz)

RGBS OUTPUTS

(VZ-45b)

IMPORTANT

41

34

35

36

39

38

42

43

44

SWITCHABLE OUTPUTS

(all Visualizers)

All outputs of the WolfVision Visualizers - except the Preview output (#31 or #43) - are switchable. Use the
IMAGE keys (#21,#22) on the control panel or the remote control to switch the signal supplied from these
outputs on and off.

Independently an image is always output by the Preview video output (#31 or #43).This output can be used
for a control monitor. A constant sync signal is supplied to all switchable outputs (even in the image off mode)
eliminating monitor image distortions when switching.

VD

S/HD

The factory-settings of the sync-outputs is HD/VD (i.e. separate horizontal and vertical sync-impulses) and sync-
on-green off. This format is the same as the one used in the computer-industry so there should be no problems
with the most multiscan-monitors or projectors.

However, if your display-device does not support separate sync-inputs but has only one sync-input (normally
marked with S) you should switch the Visualizer to CSYNC (i.e. the combined vertical- and horizontal-sync-
impulses are output on the S/HD-connector). You can switch between CSYNC and VD/HD by pressing SAVE
(#12) + IRIS dark (#19) + IRIS bright (#20) simultaneously.

If you want to use sync-on-green you can change between sync-on-green on and off by pressing SAVE (#12) +
FOCUS near (#17) + FOCUS far (#18) simultaneously. You can also change this setting in the camera-menu.
When sync-on-green is on you need only to connect R, G and B. Monitors which do not support this mode
often display a green picture.

Please note that the sync-outputs are the same on all three outputs (5 x BNC, Preview and RGB). So if you use
multiple display-devices you should use a mode which is supported by all display-devices. Many modern monitors
or projectors automatically detect the sync-mode so they should be able to work with most of the above Visualizer-
settings. On some display-devices you can also change manually between these modes.

Most projectors or computer monitors adjust themselves automatically when the VZ-45b is connected.

However some may do a wrong automatic adjustment as the signal output by the VZ-45b is not 100%
S-VGA compatible. The S-VGA standard ist 800x600 pixels at 60 Hz and the signal output by the VZ-45b
is 782x582 pixels at 50Hz.You may have to go into the setup menu of your data-projector or computer-
monitor to adjust these settings manually.

Synchronization of a projector or monitor: