Air King Exhaust Fans ASLC120 User Manual
Aslc120, Cul/hvi, Specifications exhaust fan with light
SPECIFICATIONS
EXHAUST FAN WITH LIGHT
ASLC120
Updated 7-08
Specifications subject to change without notice.
C
US
• Grill
White, polymeric grill secured in place via screw mounting
through the light housing, dimensions - 11" x 10
1/2
".
• Light Lens
High impact polycarbonate lens, secured in position using
integral tabs: easily removed if necessary.
• Light Housing
Heavy gauge cold rolled steel c/w baked enamel finish; locks in
place on the grill via two integral tabs.
• Blower Wheel
One piece polymeric wheel, 4
1/2
" diameter, 1" wide, with 10 fins.
• Motor
PSC, plug-in, 4 pole motor, life time lubrication, thermally
protected. Rated 120 volts, 60 hz., 1.6 amps.
• Fan Housing
23 ga. Galvanized metal housing, dimensions 9
1/8
" x 9" x 5
7/8
"
• Duct Collar
Plastic collar for 4" duct connection, comes complete with built
in non-metallic back draft damper for quiet operation.
• Lighting
Type A-19 medium base incandescent 100 watt maximum bulb.
• Unit Mounting
Rated Type IC for ceilings insulated to R-40. Designed to
mount in ceilings with at least 6" of clearance. The unit will
mount using the supplied mounting bars with a rough in
opening of 9
1/4
" x 9
3/8
". The housing will mount through
drywall thickness up to
3/4
".
• Single Pack Shipping Info
Box Dim: 11
1/2
" x 13
1/4
" x 9
1/2
"
UPC:
0-8316221271-8
Shipping Weight: 6 lbs.
120 CFM/4.0 SONES @ 0.10" WG.
HVI CERTIFIED 120 Volts, 1.6 amps, 60 hz.
PERFORMANCE
HVI Sones
Fan Speed
Power
Static Pressure (inches of w.g.)
@ .1 SP
RPM
Watts
0 0.05 0.1 0.125 0.25 0.375 0.5 0.625
Air Flow - CFM 126 123 120 118 110 101 92 81
4.0
1800
97
CUL/HVI
Acceptable for use over tub or shower when
installed in a GFCI protected branch circuit.
U.S.: 820 Lincoln Drive
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Canada: 110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY
DATE
FAN MODEL CFM IN RPM
WATTS AMPS SONES QTY OPTIONAL
EQUIPMENT
NUMBER
NUMBER
W.G.
&
REMARKS
5
7/8
"
4"
9"
9
1/8
"
11"
10
1/2
"