Air King Exhaust Fans ASLC70 User Manual
Aslc70, Cul/hvi, Specifications exhaust fans
SPECIFICATIONS
EXHAUST FANS
ASLC70
70 CFM/4.0 SONES @ 0.10" WG. -HVI CERTIFIED
120 Volts, 1.6 amps, 60 hz.
• Grill
White polymeric grill secured in place via screw mounting
through the light housing, dimensions - 11" x 10
1/2
".
• Light Lens
High impact polycarbonate lens, secured in position using
integral tabs; easily removed if necessary.
• Light Housing
Heavy gauge cold rolled steel c/w baked enamel finish; locks
in place on the grill via two integral tabs.
• Blower Wheel
One piece polymeric wheel, 4
1/2
" diameter, 1" wide, with 10 fins.
• Motor
Single coil plug-in, two pole motor, life time lubrication, thermally
protected. Rated 120 volts, 60 hz., 1.6 amps.
• Fan Housing
23 ga. Galvanized metal housing, dimensions 7
3/8
" x 7
5/8
" x 5
7/8
",
double metal thickness mounting tabs.
• Duct Collar
Plastic collar for 4" duct connection, comes complete with built
in non-metallic back draft damper for quiet operation.
• Lighting
100 watt maximum, type A19, medium base bulb.
CUL/HVI
Canada: 110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015
U.S.: 820 Lincoln Drive
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Updated 5-06
Specifications subject to change without notice.
• Unit Mounting
Rated Type IC for ceilings insulated to R-40. Designed to mount
in ceilings with at least 6" of clearance. The unit will mount
directly to the joist or using the supplied mounting bars with a
rough in opening of 7
5/8
" x 7
7/8
". The housing will mount through
drywall thickness up to
3/4
".
• Ventilating Area
For bathrooms up to 70 sq. ft. for other rooms up to 85 sq. ft.
• Single Pack Shipping Info
Box Dim: 11
3/4
" x 13
1/4
" x 9
3/8
"
UPC: 0-8316227611-7
Shipping Weight: 6 lbs.
C
US
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY
DATE
FAN
MODEL
CFM
IN
RPM
WATTS
AMPS
SONES
QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER
W.G.
& REMARKS
Acceptable for use over tub or shower when
installed in a GFCI protected branch circuit.
PERFORMANCE
HVI Sones
Fan Speed
Power
Static Pressure (inches of w.g.)
@ .1 SP
RPM
Watts
0
0.05
0.1
0.125
0.15
0.2
0.25
0.3
Air Flow - CFM
77
73
70
69
68
66
64
62
4.0
1725
44
5
7/8
"
4"
7
5/8
"
7
3/8
"
11"
10
1/2
"