beautypg.com

N o t e, Troubleshooting internal electrical components – Alto-Shaam 1000-SK/III User Manual

Page 25

background image

deluxe

control

smokers

installation

/

operation

/

service

manual

-

pg

. 23

S E R V I C E

A. No power. Display will not light.

1. Verify that power is available at the outlet or junction box.

2. Verify that the circuit breaker switch on the back of the unit is turned on.

3. Verify that the power cord is not open. Check continuity with a VOM meter.

4. If the problem persists, call a qualified Alto-Shaam service technician at 1-800-558-8744.

B. Display is lit but unit is not heating.

Check to verify that the high limit switch located at the rear of the unit top has not been

tripped. If it has been tripped, reset by pressing in the hit limit reset button at the rear

of the oven.

After resetting, the cause of the high limit trip must be corrected. If the high limit switch

will not reset, the high limit switch is defective and must be replaced.

This is a safety

device and must not be bypassed or removed from the circuit.

C. To test air sensor:

Test air sensor by placing sensor in ice water bath and using an ohmmeter set on the ohm scale.

The reading should be 100 ohms resistance. If it is more than 2 ohms higher or lower, sensor

needs to be replaced.

D. To test probe sensor:

Test food probe by placing in ice water bath and using an ohmmeter set on the ohm scale.

The reading should be 100 ohms resistance.

TROUBLESHOOTING INTERNAL ELECTRICAL COMPONENTS

This section is provided for the assistance of qualified technicians only and is not intended for use by

untrained or unauthorized service personnel. If your Alto-Shaam

®

unit is not operating properly, check the

following before calling your Authorized Alto-Shaam Service Agent:

*

Check that there is power flow to the unit and circuit breaker switch at back of unit is turned on.

Do not attempt to repair or service the Cook & Hold unit beyond this point. Contact Alto-Shaam for the

nearest authorized service agent. Repairs made by any other service agents without prior authorization

by Alto-Shaam will void the warranty on the unit.

D A N G E R

DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.

N O T E

If the appliance has been unplugged for an

extended period of time, the Real Time Clock may

require recharging. Turn main breaker to the unit

off for 10 seconds and then restore power.

For more information, see Error Code E-60 in

the Troubleshooting section of this manual.

C A U T I O N

THIS SECTION IS PROVIDED FOR THE ASSISTANCE
OF QUALIFIED SERVICE TECHNICIANS ONLY AND
IS NOT INTENDED FOR USE BY UNTRAINED OR
UNAUTHORIZED SERVICE PERSONNEL.

D A N G E R

LOCK-OUT OR POST

BREAKER PANEL UNTIL

SERVICE WORK HAS

BEEN COMPLETED.

This manual is related to the following products: