Operating procedures ups-s2 – Vanguard UPS S2 User Manual

Page 9

background image

Operating Procedures

UPS-S2

6

4.0 PRETEST SETUP
4.1 Operating Voltages
The UPS-S2

™ operating voltages are pre-set for 90-130Vac, 50/60Hz or 210-240Vac, 50/60Hz.

at the factory.
To set the UPS-S2 for 120Vac operation, the High Range jumper is connected to terminal 7 of
the variac.
To set the UPS-S2 for 240Vac operation, the high Range jumper is connected to terminal 6 of the
variac.

Figure 3 Variac Terminals


4.2 UPS-S2 output voltage
The UPS-S2 output voltage is shown in table below:

Table 3 Typical UPS-S2 Output Voltage with 120Vac input

RANGE SETTING

HIGH RANGE

LOW RANGE

AC VOLTAGE OUTPUT

0-270Vac

0-120Vac

DC VOLTAGE OUTPUT

0-360Vdc

0-150Vdc

Table 4 Typical UPS-S2 Output Voltage with 240Vac input

RANGE SETTING

HIGH RANGE

LOW RANGE

AC VOLTAGE OUTPUT

0-250Vac

0-220Vac

DC VOLTAGE OUTPUT

0-360Vdc

0-260Vdc

120Vac Setting

240Vac Setting