2.3.10 IAnalyzer::GetRecordingOptions
Retrieves primary interface for access to recording options.
Syntax
HRESULT GetRecordingOptions (
[out, retval] IDispatch** recording_options );
Parameters
•
recording_options
–
address of a pointer to the
FwRecOptions
object primary
interface
Return values
Remarks
FwRecOptions
object is created via this method call, if call was successful.
Example
WSH:
Set Analyzer = WScript.CreateObject("CATC.FwAnalyzer")
Set RecOptions = Analyzer.GetRecordingOptions
C++:
HRESULT
hr;
IFwAnalyzer*
poFwAnalyzer;
// create FwAnalyzer object
if ( FAILED( CoCreateInstance(
CLSID_FwAnalyzer,
NULL, CLSCTX_SERVER,
IID_IFwAnalyzer,
LPVOID *)&poFwAnalyzer ) )
return;
// open trace file
IDispatch* rec_opt;
try
{
rec_opt = poFwAnalyzer->GetRecordingOptions();
}
catch ( _com_error& er)
{
if (er.Description().length() > 0)
::MessageBox( NULL, er.Description(), _T("FwAnalyzer
client"),MB_OK );
else
::MessageBox( NULL, er.ErrorMessage(), _T("FwAnalyzer
client"),MB_OK );
return 1;
}
// query for VTBL interface
IFwRecOptions* ib_rec_opt;