AllerAir A8PK7025 User Manual
Page 2
IMPORTANT NOTICE
REPLACING OR CLEANING THE PRE-FILTER
STEP A
Turn the unit off,
unplug it, and gently
lay it on its side.
STEP C
Gently press the pre-filter
flat against the inner walls
of the innermost filter.
Return the unit to an
upright position.
STEP B
Refrain from poking or sticking any object into the unit's air vents
[ Warning ]
Pre-filter Order Reference Numbers*
We recommend changing or cleaning pre-filters every one to two months.
Keep packaging in case of warranty returns
Filters are shipped in a separate box, and must be installed prior to use. Refer to Page 3.
Wipe the unit with a soft damp cloth to remove dust accumulated during shipping
Check the inlet opening for extra prefilters if ordered
Lay the unit on its casters and plug it into a 120-volt outlet with ground
Run the unit on TURBO for a few minutes to re-adjust the airflow patterns in the room
Depending on interior conditions, you may choose to run the unit on HIGH during the
day and on LOW at night*
Running the unit on LOW is energy-efficient and increases the amount of air dwell time
in the cleansing chambers
GETTING STARTED
AllerAir Industries Inc.
Toll free: 1-888-852-8247 / Fax: 1-877-688-2193 www.allerair.com
7
2
To order a new pre-filter, call AllerAir toll-free at 1-888-852-8247 during
regular business hours (EST), or send an e-mail to [email protected]
* Depending on interior dust conditions. But for chemical, smoke or VOC odors we suggest operating on the low setting
to allow for the longest dwell time and adsorbtion.
Slowly remove the dirty pre-filter
to avoid dispersing its contents.
To clean: Carefully vacuum both
sides of the filter or replace with
new.
To discard: Gently insert into a
plastic bag and discard.
AllerAir Industries Inc.
Toll free: 1-888-852-8247 / Fax: 1-877-688-2193 www.allerair.com
8000
8
8000 HEPA only
Prefilter A8FMPH18
THE ALLERAIR AIR FILTRATION SYSTEM
IMPORTANT NOTICE
ACTIVATED CARBON
Your AllerAir air purifier contains activated carbon that permanently traps dangerous airborne chemicals,
gases and odors. This vital filter should be changed approximately every two to three years, depending on
the environment in which the unit is operating. You can also upgrade your Exec, Vocarb or D unit at any
time to accommodate a larger and deeper carbon filter suitable for removing heavier concentrations of
chemicals, gases and odors.
PRE-FILTER
The pre-filter included with your unit removes larger particles and helps prolong the life of your HEPA filter.
The pre-filer should be vacuumed or replaced every three months.
LASER TESTED, MEDICAL-GRADE HEPA*
HEPA or high-efficiency particulate air filters were originally developed by the military to remove radio-
active dust, and are now the primary particle filtration systems used in hospitals, laboratories, electronic
clean rooms and any application where clean air is critical. Today, HEPA filters are widely recommended by
allergists, doctors and indoor air quality experts for home and office. They trap an amazing 99.97% of
airborne particles at 0.3 microns, including dust, hair, pollen and even some bacteria and viruses.
Depending on the particle level in the environment in which the unit is used, your HEPA filter should be
replaced every three to five years.
* Note that chemical and odor models D and DX feature a micro-particle filter which is rated to trap at least
95% airborne particles.
THE ALLERAIR ADVANTAGE
· Our units offer complete air filtration removing airborne chemicals, gases, odors and particles.
· Our deep bed, activated carbon filters last longer than the average thin filter which is generally carbon
sprayed onto a synthetic material.
· Our units do not use dangerous ozone technology
· Our units are manufactured to clean your air and therefore are not made with a plastic housing, or other
materials which may off-gas chemicals.
· Our units are powered by American-made motors that are energy efficient and cost only pennies a day to
operate.
PLANNING ON PAINTING YOUR HOME? READ THIS FIRST:
Particles from paint may clog your HEPA filter, therefore we recommended that users unplug their units and
remove the HEPA filter, storing it off-site until the paint job is complete. Due to the serious toxic nature of
paint it is also recommended that your carbon filter be replaced or refilled in the weeks after the paint job is
complete.
See, Replacing HEPA and/or carbon filters, for instructions on how