120ed deadbolt, Folger adam electric locks – Southern Folger 120ED DEADBOLT User Manual
Page 2
![background image](/manuals/352010/2/background.png)
A20
Printed in USA
FA Rev. 02-10
P.O. Box 2021, San Antonio, TX 78297
s
Ph: 210.533.1231
s
Fx: 210.533.2211
Web: www.SouthernFolger.com
s
Email: [email protected]
Optional Features________
s
Optional solenoid voltage –
230 VAC, 60Hz.
s
Key Cylinder Extension – When the
lock is keyed on the stop side of the
jamb, an extension eliminates the
need for a special, recessed frame
pocket. Specify E-3 for 3", E-4 for 4"
or E-5 for 5".
Dimensional Data________
Note: Dimensions are for information
and planning purposes only, and should
not be used as templates.
For complete details, see How to
Specify in this section.
Specifications_________
s
Case and cover – 10 gauge steel.
s
Deadbolt – Investment-cast
stainless steel, hardened,
1" throw.
s
Deadlock lever – Stainless
steel, adjustable for door
gap variations.
s
Bolt opening – Does not allow
access to mechanism.
s
Operating lever – Stainless steel
to operate with solenoid.
s
Solenoid – 120 VAC continuous
duty with stainless steel guides,
230VAC optional.
s
Springs – Stainless steel.
Electrical
Characteristics________
s
Solenoid voltage standard
(120 VAC) – 13 amps inrush - .75
amps seated.
s
Solenoid voltages optional
(230 VAC) – 6.6 amps inrush -
.38 amps seated.
s
Switches – SPDT, UL Listed, 15
amps @ 125 or 250 VAC.
FOLGER ADAM ELECTRIC LOCKS
Key:
Mogul
Door:
Swinging
Security
Level: Medium/Maximum
120ED DEADBOLT
MODEL NO.
OPERATION
DESCRIPTION
LATCHBACK
INDICATION
SWITCH
DEADLOCK
120ED-3-01
Key Holdback (3)
X
X
The chart below shows applicability of
above options to all 120ED Models.