Hook-up diagrams – LEESON Chassis Mount Control: 175136 User Manual
Page 5

175135.00REV1 / 175136.00REV1 HOOKUP DIAGRAMS
+
-
Battery
Caution:
Motor and battery wire must
be a minimum of 12 ga. and
a maximum of 6 ga.
White
Motor
Customer supplied
3PDT Center-off
Center-blocked switch
Relays may be used in place of switch, but a neutral position must be provided
to prevent plug reversing. Do not engage opposite direction until motor has
come to a complete stop. Failure to do so may result in damage to the control.
Pot High (P2-1)
Pot Wiper (P2-2)
Pot Low (P2-3)
Common (P2-4)
Inhibit (P2-5)
+Arm (P1-5)
+Battery (P1-4)
No Connect (P1-3)
-Arm (P1-2)
-Battery (P1-1)
5K
Ω
Speedpot
Orange
Red
Current Limit
Max Speed
Accel
I.R. Comp.
Min Speed
++
Optional
Inhibit
(see hook-up
below)
Customer
supplied
SPST switch
++
P1
P2
175135.00REV1 / 175136.00REV1 HOOKUP
+
-
+
-
Battery
Caution:
Motor and battery wire must
be a minimum of 12 ga. and
a maximum of 6 ga.
Pot High (P2-1)
Pot Wiper (P2-2)
Pot Low (P2-3)
Common (P2-4)
Inhibit (P2-5)
+Arm (P1-5)
+Battery (P1-4)
No Connect (P1-3)
-Arm (P1-2)
-Battery (P1-1)
5K
Ω
Speedpot
Orange
Red
White
Current Limit
Max Speed
Accel
I.R. Comp.
Min Speed
Motor
Optional
Inhibit
(see hook-up
below)
++
Customer supplied
SPST switch
++
P1
P2
175135.00REV1 / 175136.00REV1 REVERSING HOOKUP
Relays may be used in place of switch, but a neutral position must be provided to prevent plug reversing. DO NOT
ENGAGE OPPOSITE DIRECTION UNTIL MOTOR HAS COME TO A COMPLETE STOP. Failure to do so may
result in damage to the control.
Pot High (P2-1)
Pot Wiper (P2-2)
Pot Low (P2-3)
Common (P2-4)
Inhibit (P2-5)
5K
Ω
Speedpot
Orange
Red
White
SPST Switch
open = stop
close = run
P2
Pot High (P2-1)
Pot Wiper (P2-2)
Pot Low (P2-3)
Common (P2-4)
Inhibit (P2-5)
P2
SPST Switch
open = run
close = stop
Inhibit via speedpot - provides starting and
stopping through accel/decel parameters
Using inhibit input - provide fast start-
stop by bypassing accel/decel circuit
INHIBITING THE CONTROL - There are two methods that may be used to shut down the output without having
to break the battery supply (ie. inhibit the control).
4
CAUTION: DO NOT OPERATE CONTROL OUTSIDE THE
RECOMMENDED INPUT +/-10%