Standard features, Dimensions, Model selection – LEESON Chassis Mount Control: 175136 User Manual
Page 3
2
WARNING:
MAKE CERTAIN THAT THE POWER SUPPLY IS DISCONNECTED BEFORE ATTEMPTING TO SERVICE
OR REMOVE ANY COMPONENTS!!! IF THE POWER DISCONNECT POINT IS OUT OF SIGHT, LOCK IT
IN DISCONNECTED POSITION AND TAG TO PREVENT UNEXPECTED APPLICATION OF POWER.
ONLY A QUALIFIED ELECTRICIAN OR SERVICEMAN SHOULD PERFORM ANY ELECTRICAL
TROUBLESHOOTING OR MAINTENANCE.
AT NO TIME SHOULD CIRCUIT CONTINUITY BE CHECKED BY SHORTING TERMINALS WITH A
SCREWDRIVER OR OTHER METAL DEVICE.
STANDARD FEATURES
• Provides smooth variable speed capability for mobile equipment.
• Maintains variable speed control as batteries discharge.
• Adjustable min speed, max speed, i.r. compensation, current limit, and accel.
• Inhibit terminal permits optional start-stop without breaking battery lines.
• Speed potentiometer, knob, and dialplate included.
• Increases range OR running time of battery operated equipment through high
efficiency.
• Automatic current limit foldback decreases current limit to 50% of setpoint when
heatsink temperatures reach 80° C. - provides protection from overheating.
DIMENSIONS
MODEL
WIDTH
LENGTH
DEPTH
WEIGHT
INCHES (CENTIMETERS)
OZ. (g.)
175135
6.7 (17.1)
9.0 (22.9)
2.27 (5.77)
34.0 (962)
175136
6.7 (17.1)
9.0 (22.9)
2.27 (5.77)
34.0 (963)
MODEL SELECTION
CONTINUOUS CURRENT MODEL NUMBER
175135
60
175136
60
(12VDC INPUT ± 15%)
(0 - 12VDC OUTPUT)
(24/36VDC INPUT ± 15%)
(0 - 24/36VDC OUTPUT)