beautypg.com

Steelcraft products, Model, Horizontal brace connection – LA STEELCRAFT AB-30P10 User Manual

Page 2

background image

P.O. Box 90365 - Pasadena, CA 91109

DATE: 9/4/09

DRAWN BY: AFS

DO NOT SCALE DRAWING

STEELCRAFT PRODUCTS

DO NOT SCALE DRAWING

PHN 626-798-7401 FAX 626-798-1482

MODEL

AB-30P10

EXTENSION DETAILS

PARTS

HORIZONTAL BRACE CONNECTION

FRONT ARCH

2 7/8" OD

HORIZONTAL BRACE

SLEEVE FITTING

2 3/8" OD

SET SCREW

INSTRUCTIONS

NOTE: SPECIFICATIONS ARE SUBJECT TO CHANGE

1. INSTALL FRONT ARCH SIMILAR TO FRONT ARCH OF THE BASE BACKSTOP. THE EXTENSION

ARCH IS TO BE 10’-4 ½” IN FRONT OF THE BASE BACKSTOP.

2. INSERT THE TOP FRONT BRACE IN THE STUB ON THE FRONT BASE ARCH AND THE

EXTENSION ARCH. TIGHTEN THE SET SCREWS.

3. THE EXTENSION BRACES ARE TO BE SPACED AT APPROXIMATELY 10’-6” C-C. PLACE A

BRACE BAND AT THIS SPACING TO RECEIVE THE EIGHT REMAINING FRONT BRACES.

4. PLACE THE SLIP FITTING IN EACH END OF THE FRONT BRACE AND ATTACH TO THE BRACE

BANDS USING HARDWARE PROVIDED. ADJUST TO MAKE THE FRONT ARCH

PERPENDICULAR AND TIGHTEN SET SCREWS.

5. PLACE TENSION BANDS AT APPROXIMATELY 10’-0” SPACING. PLACE THE CHAIN LINK

FABRIC ON THE TOP OF THE EXTENSION AND ATTACH TO THE TENSION BARS/BANDS.

ITEM

QUANT

DESCRIPTION

A

1

CENTER FRONT TOP SECTION: 2-7/8" od GALV PIPE X w/
INTERNAL FITTINGS ON EACH END AND 1 STUB FITTINGS
WELDED AT CENTER TO RECEIVE THE CENTER VERTICAL
RIB.

B

2

LEFT AND RIGHT SIDE FRONT ARCH TOP SECTIONS MADE
OF 2-7/8" OD GALV. PIPE. BOTTOM END EXTENDS INTO
FOOTING

C

9

HORIZONTAL STIFFENERS (BRACES): 2-3/8" OD @ 4'-9"
GALV. PIPE.

D

60

2-7/8" TENSION BANDS W/ 5/16" X 1-1/4" CC BOLTS

E

22

5/8" X 1" SOCKET SET SCREWS

F

45

2" - 11 GA. X 10 ft. WIDE CHAIN LINK FABRIC

G

60

5/16" X 1-1/4" CC BOLT w/ LOCK NUT

H

14

10 ft. TENSION BARS