beautypg.com

Power behind the storage, Raid storage controllers – ATTO Technology FastStream SC 7500E User Manual

Page 2

background image

Rev 9/08

©2008 ATTO Technology, Inc. Specifications subject to change without notice.

Power Behind the Storage

Technical Specification

For More Information:

www.ATTOTech.com

or to Purchase:

www.ATTOStore.com

(716) 691-1999

Technical Features

RAID Levels

• JBOD, DVRAID, 0, 1, 4, 5, 6, 10, 40, 50 and 60 plus N-way mirroring

Key Features

Hardware Specifications

Fibre Channel Interface

• 4-Gigabit, auto-negotiates to 2/1 Gigabit devices
• Two Optical SFP (Small Form Factor Pluggable) Fibre Channel ports (5500E)

• Four Optical SFP (Small Form Factor Pluggable) Fibre Channel ports (7500E)
• Full support for direct connect for F-port fabric switches
• Class 3 and Intermix ANSI Fibre Channel Specifications
• PLDA, public loop login (NL-ports) and fabric connect (N-port)

SAS/SATA Interface

• Eight 3-Gb SAS/SATA ports via two internal SFF-8484 SAS connectors

Management Interface

• RJ-45 connector for Ethernet management port
• RS-232 serial header console port

Management

Setup and Monitoring

• Simplified one-click setup allows for system setup in just minutes
• Built in read-only drive performance monitoring allows you to gauge

storage performance while host-based applications are in use

Local and Network Management

• ExpressNAV

TM

storage manager browser-based user interface for remote

configuration, management and diagnostic capabilities

• Local diagnostics supported via CLI, Telnet and FTP
• Command line and menu-based ASCII text management access via the

Ethernet management port and ExpressNAV

Environmental & Physical Specifications

Dimensions

• 177.80mm (w) x 1U* (h) x 244mm (l)

(*Up to 3U depending on configuration)

Operating Environment

• Temperature: 5 - 40° C

Humidity: 10 - 90% non-condensing

Storage Environment

• Temperature: -40 - 70° C

Humidity: 5 - 95% non-condensing

Power

• Input: 12 VDC +- 10%, 6A

Recommended Airflow

• 11 CFM
• Ambient air not to exceed 40° C

RoHS Compliant

• Yes

Ordering Information

Model Numbers

FastStream™ SC 5500E/7500E

RAID Storage Controllers

FastStream SC Embedded

• Tunable RAID Rebuild Priority

• SCSI Enclosure Services (SES)

• Real-time Performance Metrics

• Configurable Sector Sizes to 8kB

• Application Performance Reporting • Field Upgradeable Firmware

• Local and Global Hot Spares

• Hot Swap with Auto Rebuild

• Configuration Cloning

• Battery Backed Event Log

• Drive Initialization and Verification

• ECC Protected Memory

• Partitioning of RAID Volumes

• Media Error Handling

• Port Mapping for LUN Isolation

• One button setups for Audio, Video, IT

FSSC-5500-E00 / 5500E

FSSC-7500-E00 / 7500E

This manual is related to the following products: