JuiceGoose SQ-1500 User Manual
Page 3

OPERATION
REMOTE CONTACT CLOSURE - The SQ-1500 remote control terminal
can be connected to a contact closure for remote operation. (See Re-
mote Switch Connection) Any latching switch or relay will work for
this purpose. Juice Goose recommends use of a double throw device
in order to maintain one of two contact closures at all times. Com-
puter controlled devices such as those produced by Crestron, AMX
and similar companies may be used to control the SQ-1500.
SEQUENCE SWITCH - Without a contact closure on the remote con-
trol terminal the sequence switch on the front left of the SQ-1500 will
control its operation. In the event of a failure of the SQ-1500 timing
control circuit, the Manual On switch on the front of the chassis al-
lows activation of the SQ-1500. (Note: the Manual On option does not
provide sequencing).
REMOTE SWITCH CONNECTION
The following instructions are provided to assist with connection of a
latching remote switch or relay to the five position terminal on the
back of the SQ-1500 chassis.
SINGLE POLE DOUBLE THROW
LATCHING SWITCH
In the above illustration Position 1 on the terminal should be con-
nected to the common pole on the SPDT switch or relay. Positions 4
and 5 should be connected to the other two poles. Closing Position 1
to Position 4 will begin a sequence DOWN. Closing Position 1 to Posi-
tion 5 will begin a sequence UP.