Disclaimer, Specifications – JuiceGoose SQ-1500 User Manual
Page 2

SQ-1500
SEQUENCED POWER CONTROL MODULE
SAFETY PRECAUTIONS
SQ-1500 is designed to operate at 120 volts, 60 hertz. Operation
with any voltage or frequency other than that can damage the equip-
ment and create an unsafe situation.
CAUTION #1: The SQ-1500 must be grounded. If a power extension
cord is required, use a properly insulated and grounded cord. Failure
to ground the device could expose the user to dangerous electric
shock.
CAUTION #2: There are no user serviceable parts inside the SQ-1500.
Do not open the chassis. Refer all service questions or issues to
Juice Goose or a qualified technician.
CAUTION #3: Do not expose the SQ-1500 to moisture or salty air.
Doing so could cause significant damage and create an unsafe condi-
tion.
DISCLAIMER
Juice Goose shall under no circumstances be held responsible for any
losses, damage, or injury resulting directly or indirectly from the use
of a SQ-1500 device in a manner contrary to accepted safe operating
methods or any instructions contained in this document. The user
should determine prior to use whether this product is adequate, suit-
able and safe for the application intended. Since individual applica-
tions can be subject to extreme variation Juice Goose makes no rep-
resentation or guarantee as to the suitability of the SQ-1500 for any
generally described application.
SPECIFICATIONS
CHASSIS……………………………………………………...................................................................…………………...16 Gauge Steel
DIMENSIONS (inches)………………….....................................................................……………….....………...1.72H x 19.0W x 7.0D
WEIGHT (lbs)......………………………………………………………………...................................................................................……..10.0
CIRCUIT BREAKER ………………………………..................................................................……………..Back Panel, 15A Thermal
POWER INPUT ………..………...............................................................……………...7 Foot, 14/3 SJT with NEMA 5/15P Plug
VOLTAGE INPUT.………………………………………………..............................................................…………...120 VAC at 60 Hz
POWER OUTPUTS
........................................................................Six NEMA 5/15R (Sequenced) and One NEMA 5/15R (Unswitched)
RELAY CURRENT RATING……………..................................................................……..............................................……………………...30A
POWER LINE FILTRATION…………….............................................................…………Multi-stage Filter (48dB at 30 MHz)
VOLTAGE SPIKE PROTECTION………………………………………..................................................................…….3 MOV Matrix