Inter-M V2-2000 User Manual
Page 10
![background image](/manuals/350601/10/background.png)
PROFESSIONAL POWER AMPLIFIER
8
V2-1000/2000/3000/4000
6. BALANCED XLR INPUT CONNECTORS
Each input channel is equipped with a XLR connector. You can use either balanced or unbalanced
connectors, but recommend using unbalanced only for a short distance between equipment to avoid a noise
problem. Please refer to the input connection drawings.
7. CLIP LIMITER SWITCH
The clip limiter reduces the internal operating level of the amplifier as necessary to insure that signal peaks
do not overdrive the amplifier, causing distortion or damage to the amplifier or loudspeakers. It is
recommended to leave this switch to the “ON” mode to reduce distortion and help to provide protection to
the loudspeakers.
8. HIGH PASS FILTER SWITCH
Select the switch position that is suited for your application the most. The off position allows full frequency
range signals to reach the loudspeakers. The 30Hz position reduces the signal amplitude below 30Hz to
conserve power and help protect the loudspeakers. The 50Hz position reduces the signal amplitude below
50Hz to conserve power and help protect the loudspeakers.