beautypg.com

B. when servicing the water heating system, C. heater water, D. installations in the state of california – HTP EV-80 User Manual

Page 4: E. water chemistry, Part 2, Prepare the water heater, Part 2 – prepare the water heater

background image

4

LP-04 REV. 4.15.14

Be sure to disconnect electrical power before performing service. Failure to do so could result in an electrical shock, property damage,
serious personal injury, or death.

This water heater is not designed or intended for use in space heating applications. Failure of a water heater due to unapproved use IS
NOT covered by the warranty.

B. WHEN SERVICING THE WATER HEATING SYSTEM

To avoid electric shock, disconnect electrical supply before performing maintenance.

To avoid severe burns, allow heater to cool before servicing.

C. HEATER WATER

Do not use petroleum-based cleaning or sealing compounds in a water heating system. Gaskets and seals in the system may
be damaged. This can result in substantial property damage.

Do not use “homemade cures” or “heater patent medicines”. Damage to heater, substantial property damage, and/or serious
personal injury may result.

D. INSTALLATIONS IN THE STATE OF CALIFORNIA

California Law requires that residential water heaters must be braced, anchored, or strapped to resist falling or horizontal displacement
due to earthquake motions. For residential water heaters up to 52 gallon capacity, a brochure with generic earthquake bracing
instructions can be obtained from: Office of the State Architect, 400 P Street, Sacramento, CA 95814, or you may call 916-324-5315, or
ask a water heater dealer.
However, applicable local codes shall govern installation. For residential water heaters of a capacity greater than 52 gallons, consult the
local building jurisdiction for acceptable bracing procedures.

E. WATER CHEMISTRY

Sodium less than 20mGL.

Water pH between 6.0 and 8.0

o

Maintain water pH between 6.0 and 8.0. Check with litmus paper or have it chemically analyzed by water treatment
company.

o

If the pH differs from above, consult local water treatment company for treatment needed.

Hardness less than 7 grains

o

Consult local water treatment companies for unusually hard water areas (above 7 grains hardness).

Chlorine concentration less than 100 ppm

o

Using chlorinated fresh water should be acceptable as levels are typically less than 5 ppm.

o

Do not connect the boiler to directly heat swimming pool or spa water.

o

Do not fill boiler or operate with water containing chlorine in excess of 100 ppm.


Hardness: 7 grains
Chloride levels: 100 ppm
pH levels: 6-8
TDS: 2000 ppm
Sodium: 20 mGL

Failure of an electric element due to lime scale build-up on the heating surface, low pH, or other imbalance IS NOT covered by the
warranty.

PART 2 – PREPARE THE WATER HEATER

UNCRATING HEATER

– Any claims for damage or shortage in shipment must be filed immediately against the transportation company

by the consignee. Remove all sides of the shipping crate to allow the heater to be moved into its installation location.