Section 2: product overview, 1 product specifications, 2 led status – American International Electric SEG-M User Manual
Page 3
Section 2: Product Overview
2.1 Product Specifications
The chart below contains the environmental and electrical specifications.
Electrical
Voltage
12VDC (9V Min; 20V Max)
Current
150mA @ 9V; 100mA @ 20V
Environmental
Temperature
0° to 70 ° C (32° to 158° F)
Humidity
0-95% RH Non-condensing
Environment
Indoor Only
2.2 LED Status
The following diagram and chart describes the SEG LED operations.
Data Send/Recieve (Top Left)
Network Link (Top Right)
Solid
Idle
Flashing
Receiving data from
Hub Manager Pro and it is
being properly decrypted
Solid
Good Network Link
Off
No Network Link
Status (Bottom Left)
Diagnostics (Bottom Right)
Solid (with top left blinking)
1x
EEPROM Checksum Error
2x
RAM Error
3x
Network Controller Error
4x
EEPROM Checksum Error
5x
Duplicate IP Address on
the Network
Flashing (with top left blinking)
4x
Faulty Network
Connection
5x
No DHCP Response
Received
6x
Software does not Match
Hardware
Flashing Alternately with
Bottom Left
Module is in Setup Mode
Document Number: 6066005, Rev 3.2 Page 3 of 34