SilverStone ST46GF Manual User Manual
Page 9

ST46GF
08
5.2 Humidity
6. Agency Requirements
7. Redundant Power Supply Function
6.1 Safety Certification.
6.2 AC Input Leakage Current
Table 8 –Safety Certification
Input leakage current from line to ground will be less than 3.5mA rms. Measurement will be made
at 240 VAC and 60Hz.
7.1 Redundancy
The redundant power supply is N+1=N (460W+460W=460W) function power supply, each one
module is redundancy when any one module was failed. To be redundant each item must be in the
Hot swap power supply module.
Operating Humidity Range:
Non-Operating Humidity Range:
Product Safety:
RFI Emission:
PFC Harmonic:
Flicker:
Immunity against:
Electrostatic discharge:
Radiated field strength:
Fast transients:
Surge voltage:
RF Conducted
Voltage Dips and Interruptions
UL 60950-1 2000Edition, IEC60950-1, 3rd Edition
EU Low Voltage Directive (73/23/EEC) (CB) TÜV
FCC Part15 ( Radiated & Conducted Emissions )
CISPR 22,3rd Edition / EN55022: 1998 + A1: 2000)
EN61000-3-2:2000
EN61000-3-3: 1995 + A1: 2002
EN55024: 1998 + A1: 2001 and A2: 2003
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-11
20% ~ 90%RH non-condensing
5% ~ 95%RH non-condensing