3. DC Output Specification
3.1 Output Current / Loading
The following table defines power and current rating. The power supply shall meet
both static and dynamic voltage regulation requirements for minimum load condition.
Table 5 – Turn On/Off Timing
Figure 2 : Turn On/Off Timing
05
Item
Tsb_on-delay
Tac_on-delay
Tvout_holdup
Tpwok_holdup
Tpson_on_delay
Tpson_pwok
Tpwok_on
Tpwok_off
Tpwok_low
Tsb_vout
Description
Delay from AC being applied to +5VSB being within regulation.
Delay from AC being applied to all output voltages being within regulation.
All main output voltage stay within regulation after loss of AC
Delay from loss of AC deassertion of PWOK.
Delay from PSON# active to output voltage within regulation limits.
Delay from PSON# deactive to PWOK being deasserted.
Delay from output voltage within regulation limits to PWOK asserted at turn on.
Delay from +5VSB being in regulation to O/Ps being in regulation at AC turn on.
MIN
18
17
5
100
1
100
50
MAX
1500
2500
400
50
500
1000
Units
mS
mS
mS
mS
mS
mS
mS
mS
mS
mS
Delay from PWOK deasserted to output voltages (+5V, +3.3V, +12V) dropping
out of regulation limits.
Duration of PWOK being in the deasserted state during an off/on cycle using AC
or the PSON# signal.