2.2. SAFETY

CB: IEC 60950~1:2005(2nd Edition) and/or EN 60950~1:2006 +A11:2009

UL: UL 60951-1 , 2nd Edition, 2007-03-27

TUV: EN 60950-1:2006+All

3.2. INRUSH CURRENT

Maximum inrush current from power-on (with power on at any point on the AC sine)

and including, but not limited to, three line cycles, shall be limited to a level below

the surge rating of the input line cord, AC switch if present, bridge rectifier, fuse, and

EMI filter components. Repetitive ON/OFF cycling of the AC input voltage should not

damage the power supply or cause the input fuse to blow.

3. INPUT ELECTRICAL SPECIFICATIONS

3.1. AC INPUT

Nominal voltages for test purposes are considered to be within ±1.0V of nominal.

Parameter

Mi n. Nom.

Max.

Unit

Vin (115VAC)

90

115

132

VAC rms

Vin (230VAC)

180

230

264

VAC rms

Vin Frequency

47

--

63

HZ

(1)

3.3. INPUT LINE CURRENT & POWER FACTOR (P.F.)

(At Full load)

AC input Input line current P.F.@ Full Load

P.F.@ Pin=75W

115V < 3.5 Amps – rms > 0.95 > 0.8

230V < 2.0 Amps – rms > 0.9 > 0.65