8. When you have charged the system, close both manifold

handwheels. Let the compressor run and check the
manifold’s gauge pressure readings to be sure the
system is operating properly. If it is not, adjust the
system as necessary. To disconnect the manifold when
the system is operating correctly, see the steps below for
your specific manifold.

• For the 40134A manifold, first close the high side

coupler valve. Open the low side coupler valve. Then
disconnect the red high side hose from the A/C system.
After disconnecting, go to step 9.

• For all other manifolds, close both handwheels on the

manifold. Carefully remove the charging hoses from the
system. Charging is now complete.

9. Restart the A/C system, then open both manifold

handwheels. Refrigerant from both hoses will be drawn
quickly into the A/C system through the blue low side
hose.

10. When both gauges show the lowest operating pressure

recommended by the manufacturer, close the low side
valve and turn off the A/C system.

11. Close the low side coupler valve and disconnect the low

side hose from the A/C system.

REPLACEMENT PARTS LIST

1 Blue Barrel Handwheel Set

41698

2 Manifold Bar without Gauges (41600)

41694

(41700)

19690

3 Compound Gauge, blue case,

°F

40134a, 40152, 40153, 41600, 41700 Series

11794

3 Compound Gauge, blue case,

°C

40151, 41612, 42134A

11797

4 Hanging Hook

41697

5 Pressure Gauge, red case,

°F

40134a, 40152, 40153, 41600, 41700 Series

11795

5 Pressure Gauge, red case,

°C

40151, 41612, 42134A

11798

6 Flexible Holster (41600)

41691

Flexible Holster (41700)

19691

7 Red Barrel Handwheel Set

41698

8 Hex Nut

41616

9 Complete Stem Assembly,

2 required (41600 includes seat and O-rings)

41617

41700

19695

10 Sight Glass Assembly (41700)

19693

High Pressure Gauges for Model 41670:
Compound Gauge, psi

41675

Pressure Gauge, psi

41676

Because of ongoing product improvements, we reserve the right
to change design, specifications, and materials without notice.

4

3

6

7

1

122420 (Rev B, 6/03)

Manifold Operating Instructions

© SPX Corporation

9

8

2

5

For more information call toll-free
1-800-822-5561 in the continental U.S. and
Canada. In all other locations, contact your local
distributor.

MAINTAINING YOUR MANIFOLD

To keep your manifold in top operating condition:

• Periodically replace O-rings and valve seats.

• Be sure to lubricate O-rings with Robinair’s High

Vacuum Grease (part number 13033).

WARRANTY COVERAGE

Your manifold is covered by our One Year Limited War-
ranty
. We guarantee your manifold to be free from defects in
material and workmanship under normal use and service for
one year from the date of sale. See your distributor for details.

40134A, 41600

41700

INST 0740

4

5

6

1

8

9

7

10

2

5

4

3

SPX Corporation
655 Eisenhower Drive
Owatonna, MN 55060-0995 USA
Technical Services: 1-800-822-5561
Fax: 1-800-822-7805
Customer Service: 1-800-533-6127
Fax: 1-800-322-2890
Web Site: www.robinair. com