Installation, Ransburg – Ransburg Air Line and Filter Heater A13230 User Manual
Page 12

Air Line Heater / Filter Heater - Installation
Ransburg
LN-9811-14.1
10
NOTE
Always install the unit so that the “Inlet
and Outlets” are horizontal (See figure 1).
This unit is not intended for use within the
hazardous area, (Class 1, Div 1, or Zone 1).
W A R N I N G
!
NOTE
Outlet hose must be nylon with a
minimum temperature rating of 250°.
Filter heaters and air line heaters should be in-
stalled as close to the point of use as possible.
Existing or new pipelines, should be purged to
remove any collected debris.
1. Select position for the air line filter heater
system. It is vital to depressurize new or ex-
isting pipe work before installation.
2. Install air line filter heater system onto pipe-
line so that the “Inlet and Outlets” are hori-
zontal (See figure 1).
3. The unit must be installed a minimum of a 3’
radius from booth opening.
4. Mount system utilizing the mounting brackets
identified in figure 2.
5. Connect main air, bearing air, turbine pilot air
and gauge air as identified in figure 2.
6. During initial pressurization of the system, in-
let valves should be opened slowly to reduce
inlet velocities until system pressures are
stabilized. Check for leaks before putting filter
heater system into operation.
INSTALLATION