INPUTS

OUTPUTS

110 or 220VAC Main power input

The control unit requires an input signal for part detection. A limit switch, photo-eye, PLC or robot signal input is

acceptable.

The device will require field calibration to the specific application.

The control unit will provide a visual signal to alert the end user of the detection of an ungrounded part.

Two contact closures (UNGROUNDED & HV ON) are provided to signal the application of HV and the detection of

an ungrounded part.

These contacts may be hooked to a PLC, horn, or light (shown in the PLC INTERFACE section of this manual).

OTHER CONSIDERATIONS

Designed for use on non-metallic substrates only.

Accuracy of the system is dependent on part to probe detector distance staying consistent.

The probe to part distance should be set to 4 inches and should not vary more than ± one (1) inch.

Probe detector must stay clean.

Inspect the probe detector electrode every two weeks.