beautypg.com

Ransburg, Leps5002 power supply - installation – Ransburg LEPS5002 Power Supply for MicroPak User Manual

Page 14

background image

>

Whenever removing high voltage

cable(s) from equipment, ground the plug

end of the cable(s) by contacting the plug

to electrical ground. Do not touch the

plug until it has been grounded. This will

eliminate the possibility of residual charge

causing electrical shock.

W A R N I N G

!

Cut the HV cable (SSW-1064) according to the

length required and screw an EPS-4245 connec-

tor (supplied as part of part number LKIT0003,

connection kit, onto the cable end which will be

inserted into the power supply. Be careful to keep

the screw centered in the middle of the cable as

it is installed. Thread the cable end through the

metal nut and then through the rubber bushing

>

If a high voltage junction tank or switch

tank is to be used in the system, refer to

the appropriate service manual for cable

terminations and installation requirements.

NOTE

(supplied as part of the LKIT0003 kit). Insert the

cable fully into a high voltage output of the power

supply and then tighten the nut until the cable

is secure. Tighten the nut retaining screw with

very light force (see Figure 2). A LKIT0003 kit is

required for each high voltage cable connection

to the power supply when using SSW-1064 cable.

6. If an insulating sheathing is to be used around

the cable, it

MUST be of a non-absorbent

material, such as polyethylene, and should be

routed to prevent contact with or entrapment

of solvents or cleaning solutions. The cable

should

NOT be sheathed from its last point of

physical support after it enters the spray area,

to the applicator! Insulating sheathing is avail-

able from Ransburg as part number 9704-13.

7. If a cable must be routed through a metal

(or conductive) surface, cut an opening with

a minimum radius of five inches and mount

a nonconductive bulkhead therein. Route

the cable through the center of the bulkhead

and secure it with a suitable, nonconduc-

tive strain relief. (The opening may be any

configuration as long as there is at least five

inches (18 inches preferred) from the nearest

conductor.)

8. Make cable runs as short as possible by

mounting the power supply as close to the

spray device as codes and the physical envi-

ronment allow.

LEPS5002 Power Supply - Installation

11

Ransburg

CP-98-02.3