Whenever removing high voltage
cable(s) from equipment, ground the plug
end of the cable(s) by contacting the plug
to electrical ground. Do not touch the
plug until it has been grounded. This will
eliminate the possibility of residual charge
causing electrical shock.
W A R N I N G
!
Cut the HV cable (SSW-1064) according to the
length required and screw an EPS-4245 connec-
tor (supplied as part of part number LKIT0003,
connection kit, onto the cable end which will be
inserted into the power supply. Be careful to keep
the screw centered in the middle of the cable as
it is installed. Thread the cable end through the
metal nut and then through the rubber bushing
>
If a high voltage junction tank or switch
tank is to be used in the system, refer to
the appropriate service manual for cable
terminations and installation requirements.
NOTE
(supplied as part of the LKIT0003 kit). Insert the
cable fully into a high voltage output of the power
supply and then tighten the nut until the cable
is secure. Tighten the nut retaining screw with
very light force (see Figure 2). A LKIT0003 kit is
required for each high voltage cable connection
to the power supply when using SSW-1064 cable.
6. If an insulating sheathing is to be used around
the cable, it
MUST be of a non-absorbent
material, such as polyethylene, and should be
routed to prevent contact with or entrapment
of solvents or cleaning solutions. The cable
should
NOT be sheathed from its last point of
physical support after it enters the spray area,
to the applicator! Insulating sheathing is avail-
able from Ransburg as part number 9704-13.
7. If a cable must be routed through a metal
(or conductive) surface, cut an opening with
a minimum radius of five inches and mount
a nonconductive bulkhead therein. Route
the cable through the center of the bulkhead
and secure it with a suitable, nonconduc-
tive strain relief. (The opening may be any
configuration as long as there is at least five
inches (18 inches preferred) from the nearest
conductor.)
8. Make cable runs as short as possible by
mounting the power supply as close to the
spray device as codes and the physical envi-
ronment allow.
LEPS5002 Power Supply - Installation
11