This manual MUST be read and thor-
oughly understood by ALL personnel who
operate, clean and maintain this equipment.
Special care should be taken to ensure
that the WARNINGS and requirements for
operating and servicing safely, are followed.
W A R N I N G
!
The LEPS5002 must be installed outside of the
hazardous location (paint booth and areas as
outlined in NFPA 33).
GROUND CABLE
HIGH VOLTAGE CABLE
(Routing & General Guidelines)
SSW-1064
Unshielded High Voltage Cable
According to OSHA standard 1910.107, (h)(5),
high voltage cable “...shall be properly insu-
lated and protected from mechanical injury or
exposure to destructive chemicals.” To facilitate
compliance with this code, the following recom-
mendations
must be followed:
1.
NEVER route cables so that they lie on the
floor or are subject to vehicular traffic.
2.
NEVER route cables from different power
supplies along parallel paths unless they are
separated by at least 18 inches.
>
Sheathing is
NOT a safe method of
protecting a cable from wear or traffic.
W A R N I N G
!
>
Do NOT make the approach to the ap-
plicator at or below floor level. Route high
voltage cables from overhead down to the
applicator. Routing the cables up and out
of the way will result in less exposure to
dirt and traffic.
C A U T I O N
!
>
Do not locate the LEPS5002 Power
Supply near or adjacent to heat producing
equipment such as ovens, high wattage
lamps, or directly below water or steam
pipes.
C A U T I O N
!
CONNECTIONS TO THE
MICROPAK CONTROL UNIT
The 74947 dust proof and liquid tight low volt-
age cable assembly connects the LEPS5002
to the control unit through the use of a quick
disconnect circular connector located on top of
the power supply. After the cable is connected
to the power supply, make sure to tighten the
nut retaining screw with light force. This cable
assembly is supplied in lengths of 30ft, 75ft and
100ft. Refer to the MicroPak service manual for
connections to the control unit.
>
Important: Make sure that the ground
wire supplied with the power supply
(Ransburg part number 70539) is con-
nected from the grounding lug, located
on the top of the power supply, to a true
earth ground.
C A U T I O N
!
3.
ALWAYS route cable along appropriate insula-
tors.
4.
ALWAYS properly support cables at least 12
inches from metal beams. The support should
be made of material that does not conduct
electricity, such as most plastics. Ransburg
part number 45773-011, standoff insulator, is
one such support.
5.
ALWAYS route cables from overhead, down
to the applicator.