Whenever removing high voltage

cable(s) from equipment, ground the plug

end of the cable(s) by contacting the plug

to electrical ground. Do not touch the

plug until it has been grounded. This will

eliminate the possibility of residual charge

causing electrical shock.

W A R N I N G

!

Junction tank models LEPS5000-01 through -04

will accept either a high voltage tack (used on

older models) or banana plug contact (part num-

ber EPS-4245).

Cut the SSW-1064, HV cable, according to the

length required and screw an EPS-4245, connec-

tor, (supplied as part of part number LKIT-0003,

connection kit) onto the cable end which will be

inserted into the power supply. Be careful to keep

the screw centered in the middle of the cable as

it is installed. Thread the cable end through the

metal nut and then through the rubber bushing

(supplied as part of the LKIT-0003 kit). Insert the

cable fully into a high voltage tube of the junction

tank and then tighten the nut until the cable is

secure. Tighten the nut retaining screw with very

light force (see Figure 2). A LKIT-0003 kit is re-

quired for each high voltage cable connection to

the power supply when using SSW-1064, cable.

>

For connections into power supplies or

for gun cable connections, refer to the ap-

propriate service manual for cable termina-

tions and installation requirements.

NOTE

REAIII Gun Cables

Simply insert the gun cable into any of the junc-

tion tank outputs (refer to Figure 2b). Tighten the

cable nut until secure. Tighten the nut retaining

screw with very light force. A high voltage contact

spring is located at the bottom of each output tube

assembly of the LEPS5000-04, Junction Tank,

which is pressed against the high voltage tack,

located on the end of the REAIII gun cable.