CAUTION

NOTICE (NOTE)

These international safety symbols are used through-
out this manual to inform the owner of important
safety information and notices for safe and effective
use of the equipment.

Important Safety Instructions

CAUTION

Under NO circumstances should anyone enter

the water with the electrical equipment con-
nected and/or in operation. It is NEVER rec-
ommended to enter the water with the equip-
ment in operation.
Caution should be used when dealing with any

electrical equipment with moving parts.
NEVER run the unit out of water. It will dam-

age the seals and create a dangerous situation
for the operator.
Extreme caution should be used around water,

especially cold water, such as in Spring, Fall,
and Winter, which poses a hazard in and of
itself.
NEVER lift or drag the unit by the power or

light cord. If you need to pull the unit to the
side of the pond, use the anchoring ropes.
Do not use waders in deep ponds/lakes or

ponds/lakes with drop-offs, drastic slopes, or
soft bottom material.
Do not use boats that tip easily for fountain

installation, such as a canoe, and follow all
boating safety rules and regulations, including
wearing a PFD. (Personal Flotation Device)
The unit is supplied with an internal ground-

ing conductor. To reduce the risk of electrical
shock, be certain that the unit is plugged/con-
nected to an approved RCD (GFCI) protected
circuit.
A properly sized 3 phase motor control

(motor starter) with overload and short
circuit protection must be provided at time of
installation.
3 phase units (2.3, 3.3) require a startup test

after wiring to ensure proper rotation of the im-
peller. If the impeller is rotating in the opposite
direction, the unit will not perform properly
and internal damage to the unit may occur.
(See 3 phase startup procedure)
Means for disconnection must be incorporated

in the fi xed wiring in accordance with local
and national wiring rules to prevent accidental
start.
Consult a qualifi ed electrician for electrical

installation.

Unit Specs

Model

Voltage

range

Operating

amps

lock rotor

amps

2400EA

208-240

2.2@220V

6@220V

3400EA

208-240

3.4@220V

9@220V

4400EA

208-240

3.7@220V

20@220V

8400EA

208-240

8.0@220V

40@220V

3.1EA

208-240

11.9@220V

60@220V

2400EC

208-240

2.2@220V

6@220V

3400EC

208-240

3.4@220V

9@220V

4400EC

208-240

3.7@220V

20@220V

8400EC

208-240

8.0@220V

40@220V

2.3EA

190

5.2

41

2.3EHA

380

2.6

21

3.3EA

190

8.2

69

3.3EHA

380

4.1

34

2.3EC

190

5.2

41

2.3EHC

380

2.6

21

Quick Disconnect Installation

Important – Read Carefully Before Installation

Before using the connector, it is important that these
instructions are carefully read and understood to
ensure the connector system is completely water tight
and electrically safe.
IF IN DOUBT CONSULT A QUALIFIED ELECTRI-
CIAN.