beautypg.com

Sh series, General pump – General Pump SH User Manual

Page 11

background image

GENERAL PUMP

A member of the Interpump Group

SH SERIES

Page 11

Reassemble valves and head back in place

by following the disassembling steps in the

opposite sequence and use a torque wrench

at the following settings for valve cover

screws and head screws:

-Valve cover screw: 144.6 ft. lbs.

-Head screws: 397.8 ft. lbs.

NOTE:

In order to facilitate reassembling operation use our tool

1, Fig. 15 (p/n F200030140 for SH20-24, p/n F200030130

for SH26-30) or equivalent, able to hold the valve seat and

valve poppet in place when mounting the head on the

pump (see arrow Fig. 16).

11.3 Pumping unit maintenance.

The only maintenance operation required for the pumping

unit is the visual check of the amount of water drained out

by the cooling system through the hole provided

underneath the head (Fig. 7, page 9). It clearly shows

the pressure packing state of wear. Pressure packings

should be replaced when vibration and/or drop in the

operating pressure start to occur during operation.

Remove the eight head screws (1, Fig. 17).

Remove the pump head (see chapter 11.2).

Take out the collector (1, Fig. 19).