Ms series, General pump – General Pump MS Owner Manual User Manual
Page 12
GENERAL PUMP
A member of the Interpump Group
MS SERIES
Page 12
11.3 Pumping unit maintenance
The only maintenance operation required for the pumping
unit is greasing the pressure packings through the proper
greasers (1, Fig. 16).
Greasing should be carried out at even intervals at
least every 100 hours by means of a hand pump. Stop
greasing when the pump trigger becomes harder to
operate: that means the grease chamber is full. Use
top quality silicone grease (i.e. DANKELL OCILIS 250,
penetration coefficient 290 or a corresponding one).
Periodically check the amount of water drained out
by the pump through the hole provided in the lower
cover (Fig. 6). It clearly shows the pressure packing
state of wear; replace them if water dripping becomes
continuous and not intermittent.
Loosen and remove the plunger screws (1, Fig. 18).
Remove the upper cover by loosening the four screws
(1, Fig. 19).
For inspecting the pumping unit remove the head by
loosening the eight head screws (1, Fig. 17).
Push the plungers forward by rotating the crankshaft,
then introduce our tool p/n F200030050 (or equivalent)
in between the piston guide and the packing support
(1, Fig. 20).