Ms series, General pump – General Pump MS Owner Manual User Manual
Page 10
GENERAL PUMP
A member of the Interpump Group
MS SERIES
Page 10
11. MAINTENANCE INSTRUCTIONS
11.1 Crank mechanism maintenance.
Check oil level on a weekly basis by means of the two oil
dipsticks (1, Fig 8) provided with notches for min and max
levels.
If necessary, top up from the oil plug 3, Fig. 8.
Check the oil when cold and change the oil when still
hot (pump still at working temperature.).
In order to drain the oil from the pump remove the
magnetic plug 2, Fig. 8.
At every oil change clean the magnetic plug 2, Fig. 8 and
check the lower cover of Fig. 7 for grease
sediments or deposits.
OIL CHANGES
Hours
Qty.
Oil
Type
First Change
50
10.57
quarts
ISO
220
Subsequent
Changes
500
BRAND
TYPE
AGIP
ACER 220
ARAL
MOTANOL HP 220
AVIA
AVILUB RSL 220
BP
ENERGOL HL 220
CASTROL
ALPHA ZN 220
ESSO
NUTO 220
FINA
SOLNA 220
IP
HYDRUS 220
MOBIL
DTE OIL BB
SHELL
TELLUS C 220
TEXACO
REGOL OIL 220
TOTAL
CORTIS 220
Oil should be changed at least once a year.
Recommended oils:
11.2 Fluid end maintenance
The fluid end does not require periodical maintenance.
Service operations are limited to valve inspection
and/or replacement, when necessary. In order to remove
the valves:
Loosen and remove the valve cover screws (1, Fig. 9).
Tighten the two grub screws (1 Fig. 10) of each valve
cover until the complete valve unit moves upward enough
to allow easy extraction.
Valve components of each
valve unit are pressed
together in one single block
and therefore they can be
easily
replaced
and
installed back in place.
Separating the various
components of the valve
unit is carried out by
means of simple tools as
shown in Fig. 11, 12, 13 on
page 11).