7.INFORMATION ABOUT PUMP USE

The LK pump has been designed to operate with filtered water (see paragraph 9.6) and at
maximum temperature of 104

0

F (40

0

C).

Other fluids may be used only upon the approval of The Customer Service Department .

7.2 Max Flow Rate and Pressure Values

The performance figures given catalog refer to the maximum performance of the pump. Regardless of the power used,

pressure and maximum RPM values indicated on the plate may not be exceeded unless expressly authorized by the

Customer Service Department.

7.3 Lowest RPM

Any RPM value different from what is indicated in the performance table (see section 5) must be expressly authorized by

the Customer Service Department.

7.4 Recommended Lubricant Oil Types & Manufacturers
The pump is delivered with lubricant oil compliant with room temperatures ranging between 32

0

and 86

0

F (0

0

and

30

0

C ). Some recommended lubricant types are indicated in the table below; these lubricants are treated with additives

in order to increase corrosion protection and resistance to fatigue. As an alternative, Automotive SAE 85W-90 gearing

lubricants may also be used.

7.1 Water Temperature
The max water temperature is 104

0

F (40

0

C). However, it is possible to use the pump at temperatures of up

to 140

0

F (60

0

C) for short periods of time. In this case we advise consulting the Customer Service

Department.

BRAND

TYPE

GENERAL PUMP

SERIES 220

ARAL

Aral Degol BG220

BP

ENERGOL HLP 220

CASTROL

Hyspin VG 220, Magna 220

ELF

POLYTELIS 220

ESSO

NUTO 220

FINA

Cirkan 220

FUCHS

RENOLIN 220

MOBIL

DTE OIL BB

SHELL

TELLUS C 220

TEXACO

RANDO HD 220

TOTAL

CORTIS 220

Check the oil level with the oil level lights located on the

sides pos. 1, fig. 3. If necessary, top up via the oil plug pos.

3, fig. 3. To correctly check the oil level, the pump must be

at ambient (room) temperature. To change the oil the pump

must be at operating temperature, and is done by remov-

ing the plug, pos. 2, fig. 3. Checking and changing the oil

must be done as shown in section 11. The quantity

necessary is 473.3 oz. (14 liters).