d.

Wiring – Intalogix Junction Box

1.

Cells to Smart Sectional Controller (SSC)

Position

TB1

TB2

1

BLACK

(-) EXC

(-) EXC

2

RED

(+) EXC

(+) EXC

6

C

C

C

L

L

L

E

E

E

A

A

A

R

R

R

SHIELD

SHIELD

7

GREEN

(+) /SIG

(+) /SIG

8

W

W

W

H

H

H

I

I

I

T

T

T

E

E

E

(-) SIG

(-) SIG

2.

SSC to SSC or SSC to Pit Power Supply

Position

To TB3

From TB4

1

BLACK

(-) 8 VDC

(-) 8 VDC

2

GREEN

(+) 8 VDC

(+) 8 VDC

5

BLUE

DC RETURN

DC RETURN

6

SHIELD

SHIELD

SHIELD

7

W

W

W

H

H

H

I

I

I

T

T

T

E

E

E

(+) RS485

(+) RS485

8

RED

(-) RS485

(-) RS485

3.

Pit Power Supply to instrument

Position

TB1 (PPS)

To TBx (instrument)

1

BLACK

(-) 28 VAC

(-) 28 VAC

2

GREEN

(+) ACR

(+) ACR

3

BLUE

(+) 20 VDC

(+) 20 VDC

4

ORANGE

(-) ENABLE 5 VDC

(-) ENABLE 5 VDC

6

SHIELD

DC RETURN

DC RETURN

7

W

W

W

H

H

H

I

I

I

T

T

T

E

E

E

(+) RS485

(+) RS485

8

RED

(-) RS485

(-) RS485