Accessory 530 battery recharger, Safe area only, Description – Fairbanks H90-3052-D Fairbanks Scales User Manual
Page 9

50144 Rev. 4
TARE
ENTER
Press the
key to return the instrument to the
weighing mode.
The tare weight value will remain unaltered in memory
until power is removed or a new tare is entered in memory
AUTO
TARE
using either the
key or the numeric keypad.
C. Net Weighing Using AUTO TARE
ZERO
1. Press the
key. The display will read “0” and
the Center-of-Zero Legend will be ON.
2. Place the empty carrier on the platform.
AUTO
TARE
3. Press the key. The display will show “0” and
the NET Indicator will be ON. The weight of the
container on the platform will be entered into the
scales memory as a Tare weight.
4. Place the material to be weighed in the container. The
display will show the weight of the material in the
container.
The NET weight is the weight of the material placed in the
container, minus the weight of the container that was
entered as a Tare weight in Step 2.
NOTE
Net weighing of pre-packaged carriers can be
accomplished by first placing an empty carrier
that is the same as the product carrier on the
AUTO
TARE
platform, and pushing
before be-
ginning weighing operations.
8
SECTION 4:
BATTERY RECHARGER
4.1. Description
Accessory 530 Battery Recharger
is a Safe
Area Smart Charger, intended for non‐hazardous,
safe areas only. It is only used for recharging
Batteries ACC575
and
ACC575C.
This Accessory will fully charge a completely
discharged battery within sixteen (16) hours.
A charged battery can be left on the
charger without any resulting damage to
either the charger or the battery pack.
When a discharged Accessory 575 or 575C
Battery is first connected to a charger, the
status LED on the charger will be a constant
yellow.
Once the battery is fully charged, the LED will
remain a constant green.
IMPORTANT NOTE:
Use the Accessory
530 Battery Recharger in a
SAFE
AREA only
.
ACC 352.
352.