Trouble shooting guide, Problem cause solution, For overall dimensions see page 4 – Blagdon Pump X50 Metallic User Manual
Page 6
![background image](/manuals/346945/6/background.png)
HG-CF-1099 Rev. Q – 05.09.13
Page 6
TROUBLE SHOOTING GUIDE
NOTE :- Check all solutions before dismantling the pump.
PROBLEM
CAUSE
SOLUTION
Pump will not start
Air valve assembly malfunction/Seizure
Obstructed fluid line.
Obstructed diaphragm chamber.
Diaphragm failure causing fluid & excessive air to be
expelled through the exhaust.
Diaphragm seal failure.
Air valve system malfunction.
Air connected to exhaust.
Check carrier for freedom of movement. -
Clean, oil & replace.
Clean line or increase line size.
Remove obstruction.
Replace diaphragm.
Replace shaft seals.
Check all seals in valve chest assembly.
Re-connect to air inlet.
Erratic flow
Diaphragm failure on one side.
Valve ball not seating.
Suction leakage.
Diaphragm failure causing fluid & excessive air to be
expelled through the exhaust.
Diaphragm seal failure.
Air valve system malfunction.
Replace diaphragm.
Check and remove obstruction.
Check and correct.
Replace diaphragm.
Replace shaft seals.
Check all seals in valve chest assembly.
Pump strokes but will not
discharge
Excessive suction lift.
Suction line leakage.
Valve ball not seating correctly or damaged.
Suction line or strainer clogged.
Diaphragm failure.
Shorten suction line.
Check and correct.
Check and remove obstruction / replace.
Clear.
Replace diaphragm.
Fluid discharged from air
exhaust
Diaphragm Failure.
Loose frontplate.
Replace diaphragm.
Re-Torque to manual specifications.
Intermittent stroke rate
Over lubrication
Diaphragm shaft seal failure.
Air valve system malfunction.
Valve ball not seating / partially obstructed.
Shut-down pump. Remove air connection
into pump & introduce a small quantity of de-
greasing agent into air valve and replace
line. Run pump until clear.
Replace seals.
Check all seals in valve chest assembly.
Clear obstruction.
Trouble Shooting Guide & Technical Data
TECHNICAL DATA
FLUID CONNECTIONS
CAPACITY
MAX SOLIDS
MAX DISCHARGE HEAD
DISPLACEMENT
PER STROKE
2” BSP (F)
2” NPT (F)
0 - 500 Litres/Minute
(0 - 110 Gallons/Minute)
6 MM
(1/4”)
88 Meters
(289 ft)
1.9 Litres
(0.42 UK Gallons)
MAX. WORKING
PRESSURE
AIR INLET
TEMPERATURE LIMITS
PUMP WEIGHTS :-
8.6 Bar (125 psi)
3/4” BSP (F)
3/4” NPT (F)
Determined by Elastomers
(See page 3)
AA :- 35 Kg
CC :-70 Kg
CA :- 50 Kg
SA :- 60 kg
SC :- 78 Kg
SS :- 92 Kg
For overall dimensions see page 4