beautypg.com

Recycling, Important safety information, Warning – Blagdon Pump X40 Metallic User Manual

Page 11: Caution, Warning important

background image

Blagdon Pump • A Unit of IDEX Corporation • R79 Shannon Industrial Estate • Shannon, Co Clare, Ireland • Tel: +353 (0) 61 471933 Fax: +353 (0) 61 475046

www.blagdonpump.com • E-mail: [email protected]

x40mdl1sm-rev1111

Page 9

Air Operated Double Diaphragm Pump 8/05

Page 9

RECYCLING

Many components of Metallic AODD

pumps are made of recyclable materials
(see chart on page 10 for material
specifications). We encourage pump
users to recycle worn out parts and
pumps whenever possible, after any
hazardous pumped fluids are thoroughly
flushed.

This pump is pressurized

internally with air pressure

during operation. Always

make certain that all bolting

is in good condition and that

all of the correct bolting is reinstalled during

assembly.

WARNING

Before pump operation,

inspect all gasketed

fasteners for looseness

caused by gasket creep.

Re-torque loose fasteners

to prevent leakage. Follow recommended

torques stated in this manual.

CAUTION

When used for toxic or

aggressive fluids, the pump

should always be flushed

clean prior to disassembly.

WARNING

Before maintenance or

repair, shut off the com-

pressed air line, bleed the

pressure, and disconnect

the air line from the pump.

The discharge line may be pressurized and

must be bled of its pressure.

WARNING

Take action to prevent static

sparking. Fire or explosion

can result, especially when

handling flammable liquids.

The pump, piping, valves,

containers or other miscellaneous equipment must

be grounded. (See page 28)

WARNING

IMPORTANT

Read these safety warnings

and instructions in this

manual completely, before

installation and start-up

of the pump. It is the

responsibility of the purchaser to retain this

manual for reference. Failure to comply with

the recommendations stated in this manual will

damage the pump, and void factory warranty.

WARNING

Airborne particles and loud

noise hazards.
Wear ear and eye protection.

Before doing any main-

tenance on the pump, be

certain all pressure is

completely vented from the

pump, suction, discharge,

piping, and all other openings and connections.

Be certain the air supply is locked out or made

non-operational, so that it cannot be started while

work is being done on the pump. Be certain that

approved eye protection and protective clothing

are worn all times in the vicinity of the pump.

Failure to follow these recommendations may

result in serious injury or death.

WARNING

WARNING

In the event of diaphragm

rupture, pumped material

may enter the air end of the

pump, and be discharged

into the atmosphere. If

pumping a product which is hazardous or toxic,

the air exhaust must be piped to an appropriate

area for safe disposition.

IMPORTANT SAFETY

INFORMATION

CE

Pump complies with EN809 Pumping
Directive and Directive 98/37/EC Safety of
Machinery, and ATEX 100a Directive
94/9/EC Equipment for use in Potentially
Explosive Environments.

I M2 c/b T5
II 2GD b T5

I M2 c T5

II 2GD T5

Pump complies with EN809 pumps and pumping

systems and Directive 2006/42/EC

Machinery, and ATEX 95a Directive

94/9/EC Equipment for use in Potentially

Explosive Environments.

(See page 21)