Blagdon Pump X06 FDA User Manual
Page 4
![background image](/manuals/346934/4/background.png)
HG-CF-1129 Rev. G - 30.11.09
Page 4
FLUID CONNECTIONS
CAPACITY
MAX SOLIDS
MAX DISCHARGE HEAD
DISPLACEMENT/STROKE
1/2” / 3/4” TRI-CLAMP SIZE
Other options available
0 - 18 Litres/Minute
(0 - 3.9 Gallons/Minute)
1 MM
(1/16”)
88 Meters
(289 ft)
0.015 Litres
(0.003 UK Gallons)
MAX. WORKING PRESSURE
AIR INLET
TEMPERATURE LIMITS
PUMP WEIGHTS :-
8.6 Bar (125 psi)
1/4” BSP (F)
Determined by Elastomers
SS :- 4.0 Kg
TECHNICAL DATA
Caution -
Operating temperature limitations are as follows:
Operating Temperatures
Materials
Maximum
Minimum
Optimum
Virgin PTFE -
Chemically inert, virtually impervious. Very few chemicals are known to react chemically with
PTFE : molten alkali metals, turbulent liquid or gaseous fluorine and a few fluoro-chemicals such as chlorine
trifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures.
356
o
F
180
o
C
32
o
F
0
o
C
50
o
to 212
o
F
10
o
to 100
o
C
TYPICAL CODE =
B06. 04. S S. B B. T T S - P 1
WETTED COMPONENTS
S : 316L STAINLESS STEEL
NON - WETTED COMPONENTS
S : 316L STAINLESS STEEL
VALVE TYPE
B : BALL
SUCTION ORIENTATION
B : BOTTOM
VALVE SEATS
S : 316L STAINLESS STEEL
VALVE BALLS
T : PTFE
S : 316 STAINLESS STEEL
DIAPHRAGMS
T : PTFE
O : ONE PIECE PTFE
DESIGN LEVEL
MODEL
B06 : STANDARD
X06 : ATEX CAT. 2
SUFFIX
P : BSP CONNECTIONS
P1: TRI-CLAMP CONNECTIONS
ELECTRO - POLISHED
IMPORTANT
This pump should be used in accordance with the requirements of the Safety, Health & Welfare at Work Act 2005.
All business conducted subject to IDEX Pump Technologies, Ireland. Terms and Conditions of Sale, available on request.
IDEX Pump Technologies (Ireland) Ltd.,
A Unit of IDEX Corporation,
R79, Shannon, Co Clare, IRELAND.
TEL. : +353 61 471933 FAX. : +353 61 475046
Web Site : www.blagdonpump.com
E-Mail