Pl-1746 specifications – Electro Cam PL-1746 User Manual
Page 6

Specifications continued...
6
Plug-In Module
PL-1746-C01-R1
PL-1746-C02-E1-S
PL-1746-C04-R1
Part Numbers
PL-1746-C02-R1
PL-1746-C03-E1-S
PL-1746-C03-R1
Electrical
Input Power
Backplane Power
I/O Power
Permanent Memory
Environment
Operating Temp.
Storage Temp.
Humidity
20-30 VDC. Keypad/display is
powered from controller.
5VDC @ 500 mA max.
0
°
to 55
°
C (32
°
to 131
°
F)
-40
°
to 70
°
C (-40
°
to 160
°
F)
95% maximum relative
non-condensing
Keypad/Display: NEMA 4
PL
µ
S Module: 0.5 lbs (0.2 kg)
Keypad/Display: 0.5 lbs. (0.2 kg)
Mounts in SLC-500 chassis.
Brackets accept EN-50035 (“G” profile)
or EN-50022 (“Top Hat” profile) DIN Rail
8 sinking
†
or sourcing
†
DC inputs,
optically isolated (1st rack only).
10-30 VDC
11 mA @ 24 VDC
2
µ
s max.
PL-1746 Specifications
†
See page 4 for sinking/sourcing definitions.
20-30 VDC. Keypad/display is
powered from controller.
5VDC @ 500 mA max.
5 VDC @ 500 mA max.
20-30 VDC, 80 mA + 150 mA
per keypad + 230 mA per rack.
Example: Total = 840 mA with 2 keyboards and 2
racks.
Certain types of power supplies employ a self
protection feature called current fold back
limiting. The inrush currents of the high efficiency
switching regulators may cause power supplies to
enter current limit mode. Power supplies with
current fold back limiting should be sufficient to
supply three times the steady state current of the
system.
Inrush current @ 30v, 40 amps max. for 600
µ
s
(2 keyboards, 2 racks)
20-30 VDC @ 90 mA max. + 150 mA
per PS-6400 keypad
Certain types of power supplies employ a self
protection feature called current fold back
limiting. The inrush currents of the high efficiency
switching regulators may cause power supplies to
enter current limit mode. Power supplies with
current fold back limiting should be sufficient to
supply three times the steady state current of the
system.
EEPROM (no battery required)
EEPROM (no battery required)
EEPROM (no battery required)
NEMA Rating
0
°
to 55
°
C (32
°
to 131
°
F)
-40
°
to 70
°
C (-40
°
to 160
°
F)
95% maximum relative
non-condensing
Keypad/Display: NEMA 4
0
°
to 55
°
C (32
°
to 131
°
F)
-40
°
to 70
°
C (-40
°
to 160
°
F)
95% maximum relative
non-condensing
Keypad/Display: NEMA 4
Physical
Weight
PL
µ
S Module: 0.5 lbs (0.2 kg)
Keypad/Display: 0.5 lbs. (0.2 kg)
PL
µ
S Module: 0.5 lbs (0.2 kg)
Keypad/Display: 0.5 lbs. (0.2 kg)
Mounting
Controller
Rack
Keypad/Display
Mounts up to 1000’ from controller. 0
0 to 2 keypads may be connected to
one controller.
Mounts in SLC-500 chassis.
Mounts up to 1000’ from controller. 0
0 to 2 keypads may be connected to
one controller.
Mounts up to 1000’ from controller. 0
0 to 2 keypads may be connected to
one controller.
Mounts in SLC-500 chassis.
Inputs on Rack
DC Inputs
Input ON State Voltage
Input Current
Response
Outputs on Rack
Real World Outupts
Up to 16 SLIMLINE™ modules may
be mounted on the rack. Modules
may be any mix of AC, DC, and reed
relay. All modules (except reed relay)
optically isolated.
Analog Output
Up to 2 SLIMLINE™ analog output
modules may be mounted on the rack
in addition to the 16 digital modules.
20-30 VDC @ 80 mA max. + 150 mA
per PS-6400 keypad (include power
supply warning).