American Dryer Corp. Gas/Electric/Steam AD-75HS User Manual

Page 36

background image

32

3. Steam Damper Air System Connections

The ADS-75 is manufactured with a pneumatic (piston) damper system which requires an external supply of

compressed air. The air connection is made to the steam damper solenoid valve which is located at the rear

inner top area of the dryer just in front of the electric service relay box.

b. Air Connection

Air connection to system --- 1/8-inch N.P.T.

c. No air regulator or filtration is provided with the dryer. External regulation/filtration of 80 psi must be

provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed air line just

before the dryer connection. This is necessary to insure that correct and clean air pressure is achieved.

a. Air Requirements

&