Cabinet Cleaning
Victory Refrigeration recommends periodic internal and exterior cleaning as outlined below.
Daily Exterior Cleaning
1. Clean the surface with a sponge and cleaning solution. Use a non-abrasive cleaner that does not contain
chlorine.
2. Polish with a soft cloth, wiping with the grain of the metal.
3. Once a week wipe with a film cutting agent or stainless steel polish to maintain shine.
Weekly Interior Cleaning
1. Remove all food, food related items and shelves.
2. Discontinue power to the cabinet at the main power supply circuit breaker.
3. Remove loose food particles from the interior floors, walls and ceiling.
4. Scrub all interior surfaces and door gaskets with a warm detergent solution 100°F (38°C) - 120°F (49°C)
and a soft nylon bristled brush.
5. Rinse with clear water and allow to air dry.
6. Reinstall the shelves.
7. Return power to the cabinet by resetting main power supply circuit breaker.
8. Return food to the cabinet when temperature indicator reaches safe food temperature.
Condenser Maintenance
To keep your cabinet running efficiently, it is recommended that you clean the condenser coil once every three months
or immediately after the "COH" LED displays and alarm activates (*Refer to page 5 "Alarm Codes, Descriptions &
Resolutions" Table). However, once a month is recommended if the unit is located near cooking equipment which
produces grease laden vapors, i.e. fryers, grills, steam kettles, etc.
1. Discontinue power to the cabinet at the main power supply circuit breaker.
2. Lift hinged front grill to get access to the condenser coil.
3. Use a vacuum cleaner with proper brush attachments to clean the condenser coil, compressor-motor and
related parts.
4. In extreme cases of dust and grease buildup, the condenser coil fins may require blowing out with compressed
air or cleaning with a de-greasing agent.
5. Return power to cabinet by resetting main power supply circuit breaker.
"Top of Refrigerator/Freezer Cabinet with Raised Grill Assembly"
WARNING: Failure to keep the condenser coil clean may cause premature failure of the compressor-motor
which will NOT be covered by warranty.
8
PERIODIC MAINTENANCE
PERIODIC MAINTENANCE
Prop
Rod
Condenser
Coil
- FS-2N-S1 FS-1N-S1 FSA-3D-S1-XH FSA-2D-S1-XH FSA-1D-S1-XH FS-3D-S1-XH FS-2D-S1-XH FS-1D-S1-XH FA-3D-S1 FA-2D-S1 FA-1D-S1 FSA-3D-S1 FSA-2D-S1 FSA-1D-S1 FS-3D-S1 FS-2D-S1 FS-1D-S1 RS-2N-S1-FF RS-1N-S1-FF RS-3N-S1 RS-2N-S1 RS-1N-0S1 RA-3D-S1-EW RA-2D-S-EW RA-1D-S1-EW RSA-3D-S1-EW RSA-2D-S1-EW RSA-1D-S1-EW RS-2D-S1-EW RS-1D-S1-EW RA-3D-S1 RA-2D-S1 RA-1D-S1 RSA-3D-S RSA-2D-S1 RSA-1D-S1 RS-2D-S1 RS-1D-S1