16. INSTALLER PLEASE NOTE
16.1 Before you connect the mains power, check wiring polarity.
16.2 If alarm ‘chirps’ intermittently, this sound is due to the “HUSH®” button
having been activated. Allow approximately 10 minutes for the alarm to
reset.
16.3 A smoke alarm with built-in rechargeable battery will require a minimum of
1 hours for charging to its full capacity. Make sure that there is sufficient
charge time, otherwise the alarm will ‘chirp’ sound.
16.4 If the alarm ‘chirps’ again, press the Test button to check the battery condi-
tion.
16.5 If ‘chirps’ persists, replace smoke alarm and return to your supplier for re-
placement.
NOTE: NO USER REPLACEABLE PARTS INSIDE.
17. WARNING: INSULATION TEST
17.1 UNDER NO CIRCUMSTANCES MUST AN INSULATION RESIST-
ANCE TEST BE CARRIED OUT ON A CIRCUIT TO WHICH A
SMOKE ALARM IS FITTED.
17.2 THE TEST COULD CAUSE IRREPARABLE DAMAGE TO THE
INTERNAL CIRCUITRY OF THE SMOKE ALARM AND MAKE IT
INOPERATIVE.
17.3 THE WARRANTY WOULD BE VOID UNDER SUCH CIRCUM-
STANCES.
NOTE: WEEKLY TESTING IS RECOMMENDED
!