HOW TO PREPARE THE MACHINE FOR OPERA-
TION

How To Install The Batteries
The Scrubtec machines use six 6-volt batteries. The batteries are
located in the battery compartment under the recovery tank.
To Install the batteries, follow this procedure:
1. Turn key switch off.

2. Make sure both tanks are empty.

3. Disconnect the hoses from the recovery tank (upper tank) &

unplug the vac motor and fl oat switch.

4. Remove the tank support bracket.

5. Remove the recovery tank.

6. Place the batteries in the solution tank as shown in fi gures 6a

and 6b.

WARNING!

Lifting batteries without help could result in an injury.
Get help to lift the batteries. The batteries are heavy.

WARNING!

Working with batteries can be dangerous. Always wear
eye protection and protective clothing when working
near batteries. NO SMOKING!

7. Connect the battery cables between batteries and install long

battery cable assembly as indicated. See fi gure 6a and 6b.

8. Install the tank, reconnecting hoses and plugging in vac motor

and fl oat switch connectors. Install tank support bracket.

NOTE: Charge the batteries before using the machine.