Nova-Tech Atago DD-7 Digital Differential Refractometer User Manual
Page 2
*Specifications and appearance are subject to change without notice.
ATAGO products comply with HACCP,
GMP, and GLP system standards.
11122000PP Printed in Japan
REGISTERED
ISO9001
V.01
All ATAGO products are designed and manufactured in Japan.
Headquarters: 32-10, Honcho, Itabashi-ku, Tokyo 173-0001 Japan
TEL : 81-3-3964-6156 FAX : 81-3-3964-6137
[email protected] http : //www.atago.net/
TEL : 1-425-637-2107 [email protected]
TEL : 91-22-2833-8038 / 8076 [email protected]
TEL : 86 20-38106065 [email protected]
TEL : 662-982-8718-9 [email protected]
TEL : 55 16 3916-6000 [email protected]
TEL : 39 2 36557267 [email protected]
Liquid Crystal Display (LCD)
Operation Panel
Reference Port
Sample Port
• Method of measurement : Differential optical refraction
method
• Measurement range
: 0.000 to 2.000% in concentration
(for sucrose solution)
It is possible to measure samples with refractive index
up to 1.50 (nD) by reference solutuion.
(Samples must be low in viscosity.)
• Measurement accuracy :
±0.005%
(In the case of
measurement of sucrose
solution (0 to 2%) at 30˚C)
• Unit of minimum display : 0.001%
• Display area
: Two 24-characer lines (LCD)
• Light source
: LED
• Light sensor :
Photo-diode
(dual type)
• Output RS-232C Printer : Digital printer DP-63,
DP-AD(optional)
• Ambient temperature
: 10 to 30˚C
• Power supply
: AC100 to 240V, 50/60Hz
• Power consumption :
50VA
• Dimensions
: 36(W) × 35(D) × 14(H)cm
• Weight
: 5.8kg
Specifications
The DD-7 measures solutions of up to 2% Brix concentration at the
The DD-7 measures solutions of up to 2% Brix concentration at the
extremely high-accuracy level of
extremely high-accuracy level of ±0.005% Brix.
0.005% Brix.
(Note that the range of measurement gets narrower at concentrations higher than 10% Brix.) When a reference solution of 8.000% Brix is used, for
example, the DD-7 can measure concentrations in the range of 8% to 10% Brix at resolution of 0.001% Brix and precision of measurement of
±0.005% Brix. Note: High viscosity samples may not be suitable for measurement.
• Measurement is very simple. Inject a reference solution and a sample solution to respective injection ports,
and press the Start Switch.
• Digital readings eliminate reading errors resulting from user subjectivity.
• Measurement data can be exported to a printer or computer via RS-232C connection.
Measure low-concentration food and
beverages, such as coffee, tea, diet sodas,
and herbal extracts.
Measure concentrations of sanitizers and
disinfectants, such as hydrogen peroxide
solutions, at a precision level of ±0.012% or
higher.
Measure surfactants, anti-rust agents, metal-
working fluids, and other industrial solutions
at ±0.005% Brix accuracy.
www.novatech-usa.com
Tel: (866) 433-6682
Fax: (866) 433-6684
Tel: (281) 359-8538
Fax: (281) 359-0084