Special packages, Observation tubes, Features application – Nova-Tech Atago AP-300 Series Polarimeter User Manual
Page 3: Temperature control, No temperature control, Example of angle of rotation display, Automatic polarimeter
Type A
● AP-300 (including accessories)
● Jacketed flow tube with funnel and
● temperature sensor for jacket (200mm-approximate volume 15ml)
● Inner Lid (For Tube 200mm)
* Circulating Constant Temperature Bath 60-C3
(Cat.No.1921) sold separately.
Temperature Control
Cat.No.5296
Type A
● AP-300 (including accessories)
● Unjacketed flow tube with funnel (200mm-approximate volume 15ml)
● Inner Lid (For Tube 200mm)
No Temperature Control
Cat.No.5297
Type B
● AP-300 (including accessories)
● Jacketed flow tube and temperature sensor for jacket
(100mm-approximate volume 10ml)
● Quartz Control Plate (8°, 17°, or 34°)
● Digital printer DP-AD
● Printer paper for DP-AD
● Ribbon cassette for DP-AD
● Circulating Constant Temperature Bath 60-C3 (Cat.No.1921)
Temperature Control
Cat.No.5294
Type C
● AP-300 (including accessories)
● Quartz Control Plate (8°, 17°, or 34°)
● Digital printer DP-AD
● Printer paper for DP-AD
● Ribbon cassette for DP-AD
No Temperature Control
Cat.No.5295
Type D
Options other than above mentioned 4 types are available.
Contact your nearest ATAGO representative for details.
Features
Application
Easy To Use: Simply place an observation tube
in the sample chamber of the AP-300 and press
START key
The minimum angle of rotation is 0.01°, the
minimum International Sugar Scale is 0.01°Z
Automatic Temperature Compensation Function
for International Sugar Scale with a range
between 18°C and 30°C
Conforms with ICUMSA standards
Built in memory stores the 30 most recent
measurement readings
Out-of-range measurements are indicated
instantly by graphic display
The AP-300 offers ease of use with a very
competitive price
Compact and space saving
Average Measurement Value is Displayed!
Password Function as necessary for ISO
Standard!
Measures the specific optical rotation of
medical agents
Measures the concentration of optically active
substances found in fragrance materials or
chemical compositions
Measures the international sugar scale and the
purity of sugar
Identifies the attributes of inverted sugar, etc.
Measures the specific optical rotation or the
concentration of optically active substances
Jacketed flow tube
Jacketed flow tube
with funnel
Features
Application
Example of angle of rotation display
Example of angle of rotation display
Observation tubes
Special Packages
ATAGO has prepared 4different AP-300 packages.
Automatic Temperature
Compensation Function for
International Sugar Scale
ICUMSA compliant
NEW
NEW
MAY.12, 2011 07:10
MAY.12, 2011 07:10
Explanation of measurements display
Angle of rotation
The angle of rotation is the basic numeric value measured by
polarimeters, and changes depending on the concentration of the
solution, the length of the observation tube, temperature, and/or the
measurement wavelength. It is symbolized by "
α
" and indicated in "
°
."
International Sugar Scale
The International Sugar Scale is indicated in "
°Z
."
The measurement value of 26g of sucrose in 100ml of sucrose solution
in a 200mm observation tube is 100°Z. This measurement value is
commonly used in the sugar manufacturing industry, and is usually
temperature-compensated to the reference temperature of 20°C (68°F).
The AP-300 can display the measurement value with or without temperature
compensation (Automatic Temperature Compensation, "
ATC
").
Specific Rotation
The Specific Rotation is a numeric value unique to each substance. By
definition, the specific rotation value is equivalent to the angle of
rotation obtained by a measuring a solution of 100% concentration in a
100mm observation tube (although such a measurement is actually not
practical).
Specific rotation is symbolized by "
[α]
" and indicated in "
°
."
Concentration
The Concentration is the density of a liquid solution made by dissolving
an optically active substance in water or alcohol. It is indicated in
"
g/100ml
."
Purity
The Purity is the proportion of sucrose compared to the soluble solid
content in a sample. It is indicated in "
%
." To measure the purity, input
the Brix value of the sample (which can be obtained by using an ATAGO
refractometer) into the AP-300 before taking a measurement.
Recommended for sugar industry
Recommended for pharmaceutical industry
RE-72001 : Observation tube 100mm long OT-100(A)
RE-72002 : Observation tube 200mm long OT-200(A)
RE-72036 : Jacketed flow tube 50mm
RE-72034 : Jacketed flow tube 100mm
RE-72035 : Jacketed flow tube 200mm
RE-72033 : Jacketed flow tube with funnel 100mm
RE-72032 : Jacketed flow tube with funnel 200mm
RE-72037 : Unjacketed flow tube with funnel 100mm
RE-72038 : Unjacketed flow tube with funnel 200mm
RE-72042 : Unjacketed small volume observation
tube 10mm long
RE-76015 : Sample chamber cover for Flow Cell
(Cover
only)
RE-76016 : Inner lid for 100mm tube
RE-76017 : Inner lid for 200mm tube
RE-76018 : Inner lid for 50mm tube
* To use the flow tubes, the sample chamber RE-76015
and a inner lid matching the size of the tube will be
necessary to be purchased.
* To use the flow tubes, the sample chamber RE-76015
and a inner lid matching the size of the tube will be
necessary to be purchased.
Measurement
wavelength
( )
Measurement
temperature
(TEMP)
Type of
sample tube
(TUBE)
Measurement
reading
Date and time
Mode
Name of
scale
Length of
sample tube
(L)
Operation
keys
Automatic
Polarimeter